PLANET GS-5220-16S8C User Manual
Page 86

User’s Manual of GS-5220 Series
Group Name
A string identifying the group name that this entry should belong to. The allowed
string length is 1 to 32, and the allowed content is the ASCII characters from 33
to 126.
Security Model
Indicates the security model that this entry should belong to. Possible security
models are:
any
: Accepted any security model (v1|v2c|usm).
v1
: Reserved for SNMPv1.
v2c
: Reserved for SNMPv2c.
usm
: User-based Security Model (USM)
Security Level
Indicates the security model that this entry should belong to. Possible security
models are:
NoAuth, NoPriv
: None authentication and none privacy.
Auth, NoPriv
: Authentication and none privacy.
Auth, Priv
: Authentication and privacy.
Read View Name
The name of the MIB view defining the MIB objects for which this request may
request the current values. The allowed string length is 1 to 32, and the allowed
content is the ASCII characters from 33 to 126.
Write View Name
The name of the MIB view defining the MIB objects for which this request may
potentially SET new values. The allowed string length is 1 to 32, and the allowed
content is the ASCII characters from 33 to 126.
Buttons
: Click to add a new access entry.
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
86