PLANET GS-5220-16S8C User Manual
Page 34

User’s Manual of GS-5220 Series
MGB-TLB60
1000
WDM(LC)
Single Mode
60km
1550nm / 1310nm -40 ~ 75 degrees C
10Gbps SFP+ (10G Ethernet/10GBASE)
Model
Speed (Mbps)
Connector
Interface
Fiber Mode
Distance
Wavelength (nm)
Operating Temp.
MTB-SR
10G
LC
Multi Mode
Up to 300m
850nm
0 ~ 60 degrees C
MTB-LR
10G
LC
Single Mode
10km
1310nm
0 ~ 60 degrees C
10Gbps SFP+ (10GBASE-BX, Single Fiber Bi-directional SFP)
Model
Speed (Mbps)
Connector
Interface
Fiber Mode Distance
Wavelength (TX)
Wavelength (RX)
Operating Temp.
10G
WDM(LC) Single Mode
20km
1270nm
1330nm
0 ~ 60 degrees C
MTB-LA20
MTB-LB20
10G
WDM(LC) Single Mode
20km
1330nm
1270nm
0 ~ 60 degrees C
10G
WDM(LC) Single Mode
40km
1270nm
1330nm
0 ~ 60 degrees C
MTB-LA40
MTB-LB40
10G
WDM(LC) Single Mode
40km
1330nm
1270nm
0 ~ 60 degrees C
10G
WDM(LC) Single Mode
60km
1270nm
1330nm
0 ~ 60 degrees C
MTB-LA60
MTB-LB60
10G
WDM(LC) Single Mode
60km
1330nm
1270nm
0 ~ 60 degrees C
It is recommended to use PLANET SFP / SFP+ on the Managed Switch. If you insert an SFP / SFP+
transceiver that is not supported, the Managed Switch will not recognize it.
1.
Before we connect the GS-5220 series to the other network device, we have to make sure both sides of the SFP
transceivers are with the same media type, for example: 1000BASE-SX to 1000BASE-SX, 1000Bas-LX to 1000BASE-LX.
2.
Check whether the fiber-optic cable type matches with the SFP transceiver requirement.
To connect to 1000BASE-SX SFP transceiver, please use the multi-mode fiber cable with one side being the male
duplex LC connector type.
To connect to 1000BASE-LX SFP transceiver, please use the single-mode fiber cable with one side being the male
duplex LC connector type.
Connect the Fiber Cable
1.
Insert the duplex LC connector into the SFP / SFP+ transceiver.
2.
Connect the other end of the cable to a device with SFP / SFP+ transceiver installed.
3.
Check the LNK/ACT LED of the SFP / SFP+ slot on the front of the Managed Switch. Ensure that the SFP / SFP+
transceiver is operating correctly.
4.
Check the Link mode of the SFP / SFP+ port if the link fails. To function with some fiber-NICs or Media Converters, user
has to set the port Link mode to “10G Force”, “1000M Force” or “100M Force”.
Remove the Transceiver Module
1.
Make sure there is no network activity anymore.
2.
Remove the Fiber-Optic Cable gently.