The evaluation board is easily prepared for use. Only minor preparations (just by soldering cables for DC supplies, input
PWM & /Fault + /UVLO feedback signals, proper cables for HV+/HV- high voltage bus, and load connections) are re-
quired. The evaluation board is having a default connection as shown in Table1 when shipped to customer. Customer is
free to select a different LED driving schemes and whether negative supply is used, as shown in the Table.
Table 1
No.
LED is
driven by
CON2
V
CC1
V
CC2
V
EE2
V
E
J1
J2
Remarks
30 V maximum
1
V
LEDDRV
s/c
+5 V
External
+15V~30V
External
0V ~ -15V
External
0 V
s/c
s/c
Default
–3 external supplies needed for V
CC1
, V
CC2
and V
EE2
2
V
LEDDRV
s/c
+5 V
External
+15V~30V
External
s/c
0 V
s/c
*1
Simplest
–2 external supplies needed for V
CC1
&
V
CC2
3
Micro-
controller
(external)
open
+5 V
External
+15V~30V
External
0 V ~ -15 V
External
0 V
s/c
s/c
LED’s driven externally
–3 external supplies needed for V
CC1
,
V
CC2a
& V
CC2b
4
Micro-
controller
(external)
open
+5 V
External
+15V~30V
External
s/c
0 V
s/c
*1
LED’s driven externally
–2 external supplies needed for V
CC1
&
V
CC2
Notes:
*1. Whether J2 can be shorted depends on the drive signals (for connection to LED+ and LED-) from the Microcontroller.
*2. Since Miller Clamp function is built-in, -ve supply for VEE2 can be omitted, so VEE2 can be shorted to VE externally.
Note:
As the Desat diode’s breakdown voltage is rated at 1k V, IGBT must be selected with V
CES
<1 kV, and maximum HV+ voltage plus flyback voltage of
load inductor must be <1 kV).