Avago Technologies MegaRAID SAS 9341-4i User Manual
Page 11

Avago Technologies
- 11 -
MegaRAID SAS Device Driver Installation User Guide
June 2015
Windows Driver Installation
MegaRAID Primary Storage
read performance. If your computer regularly performs random read requests, choose a smaller strip size. The
default is 64 KB.
— Access Policy: Select the type of data access that is allowed for this virtual drive.
RW: Permit read/write access. This setting is the default.
Read Only: Permit read-only access.
Blocked: Do not permit access.
— Read Policy: Specify the read policy for this virtual drive.
Normal: Disable the read-ahead capability. This setting is the default.
Ahead: Enable read-ahead capability, which permits the controller to read sequentially ahead of requested
data and to store the additional data in cache memory, anticipating that the data will be needed soon. This
setting speeds up read operations for sequential data, but little improvement exists when accessing random
data.
— Write Policy: Specify the write policy for this virtual drive.
WBack: In Write Back mode, the controller sends a data transfer completion signal to the host when the
controller cache has received all of the data in a transaction. This setting is recommended in Standard mode.
WThru: In Write Through mode, the controller sends a data transfer completion signal to the host when the
drive subsystem has received all of the data in a transaction. This setting is the default.
Write Back with BBU: Select this mode if you want the controller to use Write Back mode, but the controller
either has no battery backup unit (BBU) or the BBU is bad. If you do not choose this option, the controller
firmware automatically switches to Write Through mode if it detects a bad or missing BBU.
NOTE
You can use Write Back mode with or without a battery. You should
use either a battery to protect the controller cache or an
uninterruptible power supply (UPS) to protect the entire system. If you
do not use a battery or a UPS, and a power failure occurs, you risk
losing the data in the controller cache. Although you can enable or
disable the disk cache, you should disable it. If you enable the disk
cache, the drive sends a data transfer completion signal to the
controller when the drive cache has received all the data in a
transaction. However, the data has not been actually transferred to the
- MegaRAID SAS 9341-8i MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9380-8e MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9380-4i4e MegaRAID SAS 8204ELP MegaRAID SAS 8204ELP (Channel) MegaRAID SAS 8204XLP MegaRAID SAS 8204XLP (Channel) MegaRAID SAS 8208ELP MegaRAID SAS 8208ELP (Channel) MegaRAID SAS 8208XLP MegaRAID SAS 8208XLP (Channel) MegaRAID SAS 8300XLP MegaRAID SAS 8308ELP MegaRAID SAS 8344ELP MegaRAID SAS 84016E MegaRAID SAS 84016E (Channel) MegaRAID SAS 8408E MegaRAID SAS 8480E MegaRAID SAS 8704ELP MegaRAID SAS 8704ELP (Channel) MegaRAID SAS 8704EM2 MegaRAID SAS 8704EM2 (Channel) MegaRAID SAS 8708ELP MegaRAID SAS 8708ELP (Channel) MegaRAID SAS 8708EM2 MegaRAID SAS 8708EM2 (Channel) MegaRAID SAS 8880EM2 MegaRAID SAS 8880EM2 (Channel) MegaRAID SAS 8888ELP MegaRAID SAS 8888ELP (Channel) MegaRAID SAS 0260CV-8i MegaRAID SAS 0260DE-8i MegaRAID SAS 0260DE-8i (Channel) MegaRAID SAS 9265-8i MegaRAID SAS 9280DE-8e MegaRAID SAS 9280DE-8e (Channel) MegaRAID SAS 9285-8e MegaRAID SAS 0260CV-4i