beautypg.com

J1a5 – Avago Technologies MegaRAID SAS 9240-4i User Manual

Page 43

background image

LSI Corporation

- 43 -

6Gb/s MegaRAID SAS RAID Controllers User Guide

August 2013

MegaRAID SAS RAID Controller Characteristics

6Gb/s MegaRAID SAS RAID Controller Family

J1A4

Activity LED header

2-pin connector

Connects to an LED that indicates activity on the drives
connected to the controller.

J1A5

Individual PHY and Drive Fault Indication header

Ports 0 to 3

Ports 4 to 7

2x8-pin header

Connects to an LED that indicates whether a drive is in a
fault condition. There is one LED per port. When lit, each LED
indicates the corresponding drive has failed or is in the
Unconfigured-Bad state.

The LEDs function in a direct-attach configuration (there are
no SAS expanders). Direct attach is defined as a maximum of
one drive connected directly to each port.

J1A7

I

2

C Enclosure Management connector

3-pin connector

Supports SES (SCSI enclosure services) over I

2

C through an

internal I

2

C backplane cable.

J1B1

Serial EEPROM (SBR)

2-pin connector

Provides controller information, such as the serial number,
revision, and manufacturing date. The default is no
shunt installed.

J2B1

x4 SAS Ports 0 to 3 Internal connector

SFF-8087 mini SAS 4i internal connector

Connects the controller by cable to SAS drives or
SATA drives.

J2B2

x4 SAS Ports 4 to 7 Internal connector

SFF-8087 mini SAS 4i internal connector

Connects the controller by cable to SAS drives or
SATA drives.

Table 9 MegaRAID SAS 9265CV-8i RAID Controller – Jumpers and Connectors (Continued)

Jumper/

Connector

Type

Description

J1A4 +vea

k

-ve

J1A5

+ve

-ve

a

k

J1A7

1

2
3