MegaRAID SAS RAID Controller Characteristics

6Gb/s MegaRAID SAS RAID Controller Family

The following table describes the jumpers and the connectors on the MegaRAID SAS 9260-16i RAID controller. It
includes diagrams that show Pin1 and its orientation for several of the connectors.

Table 5 MegaRAID SAS 9260-16i RAID Controller – Connectors

Jumper/

Connector

Type

Description

J1A2

Universal Asynchronous Receiver/Transmitter (UART)
for the Expander

4-pin connector

Reserved for LSI use.

J1B1

LED Locate and Fault Indication header

Ports 0 to 3

Ports 4 to 7

2x8-pin connector

Connects to an LED array that indicates whether a drive is in
a fault condition. There is one LED per port. When lit, each
LED indicates the corresponding drive has failed or is in the
unconfigured-bad state.

The LEDs function in a direct-attach configuration (there are
no SAS expanders). Direct attach is defined as a maximum of
one drive connected directly to each port.

NOTE This header is used for RAID controllers with internal
SAS ports only.

J1B3

Advanced Software Options Hardware Key header

2-pin header

Enables support for the Advanced Software Options
features, which include CacheCade, FastPath, Recovery, and
SafeStore disk encryption.

J1C1

IPMI-style I

2

C connector

3-pin connector

Supports SES (SCSI enclosure services) over I

2

C through an

internal I

2

C backplane cable.

J1L1

Remote Battery Backup connector (on the rear of the
controller)

20-pin connector

Connects the optional LSIiBBU07 intelligent Battery
Backup Unit or the optional LSIiBBU08 unit to the RAID
controller remotely.

J2B1

x4 SAS Ports 0 to 3 Internal connector

SFF-8087 x4 internal mini SAS connector

Connects the controller by cable to SAS drives or
SATA 2 drives.

J2B2

x4 SAS Ports 4 to 7 Internal connector

SFF-8087 x4 internal mini SAS connector

Connects the controller by cable to SAS drives or
SATA 2 drives.

J2D1

Standard Edge Card connector

The RAID controller interfaces with the host system though a
standard edge card.

This interface provides power to the board and an I

2

C

interface connected to the I

2

C bus for IPMI.

J1B1

PORT 0

PORT 7

+ve

-ve

a

k