Chapter 2: megaraid sas hardware installation, 1 requirements, 2 quick installation – Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 20: 1 requirements 2.2 quick installation

LSI Corporation
- 20 -
6Gb/s MegaRAID SAS RAID Controllers User Guide
August 2013
MegaRAID SAS Hardware Installation
Requirements
Chapter 2: MegaRAID SAS Hardware Installation
2.1
Requirements
The following items are required to install a MegaRAID 6Gb/s SAS RAID controller:
A MegaRAID SAS 92xx RAID controller
A host system with an available x8 PCIe 2.0 slot
NOTE
These controllers also work in PCIe first generation slots. The PCIe
software is backward compatible with previous revisions of the PCI
bus and the PCI-X bus.
The MegaRAID Universal Software Suite CD, which contains the drivers and documentation
The necessary internal cables, external cables, or both
SAS drives or SATA drives
NOTE
Make sure to use an uninterruptible power supply.
2.2
Quick Installation
The following steps quickly install your MegaRAID 6Gb/s SAS RAID controller. These steps are for experienced
computer users or installers.
Section 2.3, Detailed Installation
, contains the steps for all other users to follow.
1.
Turn off the power to the system and all drives, enclosures, and system components, and disconnect the PC
power cord.
2.
Open the cabinet of the host system by following the instructions in the host system technical documentation.
3.
Check the jumper settings to make sure that they are in the desired position. The jumpers are set at the factory.
and you usually do not need to change them.
NOTE
See
MegaRAID SAS RAID Controller Characteristics
, for
detailed information about the jumpers and the connectors.
4.
Install the MegaRAID 6Gb/s SAS RAID controller in the server, and connect SAS devices or SATA II devices to it.
Make sure that the cables you use conform to all specifications.
5.
Perform a safety check.
a.
Make sure that all cables are attached correctly.
b.
Make sure that the RAID controller is installed correctly.
c.
Close the cabinet of the host system.
6.
Reconnect the power cords to the system.
7.
Turn on the power to the system.
Make sure that the power is turned on to any external drives before the power is turned on to the host computer.
If the computer is powered up before these devices, the devices might not be recognized.
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 9285-8ecv