beautypg.com

Avago Technologies MegaRAID SAS 9240-4i User Manual

Page 30

background image

LSI Corporation

- 30 -

6Gb/s MegaRAID SAS RAID Controllers User Guide

August 2013

MegaRAID SAS RAID Controller Characteristics

6Gb/s MegaRAID SAS RAID Controller Family

3.1.2.1

MegaRAID SAS 9260-4i, SAS 9260-8i, and SAS 9260DE-8i RAID Controllers – Board Layout and
Jumper/Connector Information

This subsection provides the board layout, and the connector and jumper information for the MegaRAID SAS 9260-4i,
SAS 9260-8i, and SAS 9260DE-8i RAID controllers. The following figure shows the connectors on the MegaRAID SAS
9260-8i RAID controller.

NOTE

The MegaRAID SAS 9260-4i RAID controller has the same connectors
as the MegaRAID SAS 9260-8i RAID controller except for the JT7
connector, which supports ports 4 to 7. The MegaRAID SAS 9260DE-8i
RAID controller has the same connectors as the MegaRAID SAS 9260-8i
RAID controller.

Figure 10 Card Layout for the MegaRAID SAS 9260-8i RAID Controller

NOTE

JT1, JT2, and JT4 are behind the LSIiBBU07 unit when the iBBU unit is
installed, but they are still accessible.

NOTE

Pin 1 on the headers and connectors is highlighted in red in this figure.

The following table describes the jumpers and connectors on the MegaRAID SAS 9260-4i, SAS 9260-8i, and
SAS 9260DE-8i RAID controllers.

Table 4 MegaRAID SAS 9260-4i, SAS 9260-8i, and SAS 9260DE-8i RAID Controllers – Jumpers and Connectors

Jumper

Type

Description

JT1

Write-Pending Indicator (dirty cache)
LED connector

2-pin connector

Connects to an LED that indicates when the data in the cache has yet to be
written to the storage devices. Used when the write-back feature is enabled.

JT2

SAS Activity LED header

2-pin connector

Connects to an LED that indicates drive activity.

JT3

Battery Backup Unit connector

20-pin connector

Connects the optional LSIiBBU07 intelligent Battery Backup Unit or the optional
LSIiBBU08 unit to the RAID controller remotely.

JT4

Global Drive Fault LED header

2-pin connector

Connects to a single LED to indicate whether any drive is in a fault condition.

JT6

x4 SAS Ports 3 to 0

SFF-8087 x4 internal mini SAS connector

Connects the cables from the RAID controller to SAS drives, SATA drives, or a
SAS expander.

3_01400-00

Por

t

3-0

JT10

JT3

JT4

JT2

JT1

JT12

JT8

JT13

JT11

JT9

Port

7-4

JT7

JT6