Table 2-3. compatibility mode differences, Compatibility mode differences -4, Ar. 2.2.2) – KEPCO TMA 4882-27 User Manual
Page 22
2-4
TMA 4882-27 021910
2.2.2
START-UP LANGUAGE/COMPATIBILITY MODE/GPIB ADDRESSING DEFAULT (SEE FIG-
URE 2-1)
Program Mode Bits P1 (DIP switch position adjacent to Address Selector Switch A5, see Figure
2-1) and P2 (right-most position) control the start-up command language, secondary GPIB
addressing with SCPI, and Compatibility Mode as defined in Table 2-2.
Language - Selection is provided to choose either SCPI or CIIL command language. If SCPI is
selected, you can also choose to implement either primary or secondary GPIB addressing. CIIL
is select by changing P1 to 1 and P2 to 0. SCPI selection with secondary addressing is selected
by changing P1 to 0 and P2 to 1.
Compatibility Mode - Certain features of the TMA 4882-27 can be configured to be fully 488.2/
SCPI compatible (Mode 0) or to be backward compatible with previous Kepco products (Mode
1). Differences between Mode 0 and Mode 1 functionality are explained in Table 2-3.
TABLE 2-2. START-UP LANGUAGE/COMPATIBILITY MODE/GPIB ADDRESSING SELECTION
P1
P2
LANGUAGE
COMPATIBILTY MODE
(See Table 2-3)
GPIB ADDRESSING
0*
0*
SCPI
MODE 1
Primary
0
1
SCPI
MODE 1
Secondary
1
0
CIIL
Not Applicable
Not Applicable
1
1
SCPI
MODE 0
Primary
* Factory Default Configuration = P1 and P2 set to 0.
TABLE 2-3. COMPATIBILITY MODE DIFFERENCES
FUNCTION
MODE 0
(fully 488.2/SCPI compatible)
MODE 1
(backward compatible with previous Kepco products)
Device Clear
Clears internal registers but leaves
output voltage and current unchanged.
Clears internal registers, sets output voltage and current
to zero, sets output to OFF, and, if unit incorporates
relays, opens relays.
Status
Uses Status Instrument Registers.
Does not use Status Instrument Registers.
PON enable
All status register enables are set to 0. All status register enables are set to 32767.
SYST:VERS?
Returns 1997.0.
Returns blank string.