3 independent operation - remote sensing, Independent operation - remote sensing -7 – KEPCO RA 19-7B Operator Manual User Manual
Page 19

RA 19-7B 011409
2-7
2.4.1.3
INDEPENDENT OPERATION - REMOTE SENSING
Remote sensing is accomplished by connecting +Load to (S+) and –Load to (S–). Figure 2-4
illustrates remote sensing for PS6 and PS7 using wires connected to the I/O mating connector.
NOTE: The internal DIP switch settings established at the factory for positions 1 and 2 of the
associated DIP switch MUST be changed to OFF (open) if remote sensing is chosen.
Positions 3 and 4 (connecting sense lines in parallel) and Position 5 (current share) must be set
to OFF. Configure Positions 6, 7, and 8 (alarms) per PAR. 2.4.4.
FIGURE 2-4. INDEPENDENT OPERATION, REMOTE SENSING FOR PS6 AND PS7 USING
EXTERNAL WIRING AT I/O MATING CONNECTOR, SIMPLIFIED DIAGRAM