beautypg.com

Figure 1-2. temperature derating, Temperature derating -3, 3 table 1-2. general specifications (continued) – KEPCO HSM Series User Manual

Page 9: Figure 1-1. figure 1-2. temperature derating

background image

HSMSERIES OPR 052912

1-3

TABLE 1-2. GENERAL SPECIFICATIONS (CONTINUED)

FIGURE 1-1.

FIGURE 1-2. TEMPERATURE DERATING

CHARACTERISTIC

REQUIREMENT

SIGNAL AND CONTROL

Remote Error Sensing

3.3V & 5V Models 0.25V per wire

All other Models

0.8V per wire

Remote On/Off Control

Isolated TTL-compatible signal; either logic
high or logic low will disable output.

Load Sharing

Within 5% of load when connected via load
sharing wire (see PAR. 2.7.6).

Load Monitor

0-5V analog signal proportional to output
load current; 5V at 100% of rated load.

Status Flags

(Form C dry relay contacts)

(See PAR. 3.14.)

(See Notes 5 and 7.)

POWER

Indicates low source
voltage; signal
asserted a minimum of
5 msec prior to loss of
output voltage.

OUTPUT

Indicates HSM Power
Supply in normal
operating mode.

OVERTEMP

Indicates HSM Power
Supply in
overtemperature
shutdown.

FAN FAIL

Indicates failure of
internal cooling fan.

Auxiliary Voltage

(Isolated)

4.75-5.25V d-c output, 0 - 100mA,
parallelable, output isolated (500 V d-c),
Input isolated (SELV) (See Operating
Instructions, PAR. 3.11).

Voltage Set Programming

Mode selected by

internal switches

(See Note 6.)

(See PAR. 3.3.)

Internal

Multiturn pot

External 1

Resistance: 0-50K

External 2

0-10V, 500µA

max

Current Limit

Programming

Internal

Multiturn pot

External

0-10V, 500µA

max

CHARACTERISTIC

REQUIREMENT

ENVIRONMENT

Temperature Range

Operating

0 to 50° C: rated load;
50° C to 71° C: derate by
2.5%/° C, see Figure 1-2.)

Storage

-40 to +85° C

Cooling

Internal d-c fan (inlet, exhaust as indicated in
Figure 1-3).

Humidity

0-95% RH (non-condensing), Operating and
Storage.

Shock

Non-operating, 20g, 11msec 50%, half sine, 3
axes, 3 shocks each axis

Vibration

5-10Hz

10mm, double amplitude

10-55Hz

2g

Altitude

Sea level to 10,000 feet

PHYSICAL

Dimensions

See Figure 1-3.

Weight

16 lbs. (7.3Kg)

Source Connections

3-pin power entry module (compatible with IEC
320/C19 molded line cord plug.

Load Connection

Two bus bars (+ and -)1.0 x 0.125 inch, copper
w/bright nickel finish

Signal Connection

37-pin D-subminiature connector (male)

NOTES 5: Status flags are isolated and operate independently.

6: The POWER/DCFAIL fault detector window tracks pro-

grammed output voltage, however, the overvoltage protection
trip point remains unaffected.

7. Form C contacts: rated from 30V d-c/1A to 60V d-c/0.3A.