Table 3-2 provides an operating matrix of the output status function; see Figure 3-6 for timing
relationships. The output voltage fault limits are ±5% of programmed output voltage, while the
undercurrent fault limit is <70% of required module current; signal reset requires output voltage
recovery to within the specified ±1% regulation range and/or module current recovery to >85%
of required module current, respectively.

3.14.3

OVERTEMP STATUS FLAGS

This fault is generated in the event that either the input or output module heatsink temperature
rises above a safe operating level; output regulator shutdown occurs simultaneously. Recovery
occurs automatically upon reduction of internal temperatures to normal levels.

3.14.4

FANFAIL STATUS FLAGS

This fault is g

enerated in the event of a failure of the internal cooling fan; a delay of approximately 5 sec-

onds is incorporated to prevent nuisance indications at turn-on. Reset occurs when fan operation
resumes.

TABLE 3-2. FAULT DETECTOR OPERATION