KEPCO HSM Series User Manual
Kepco, Operator’s manual, Hsm series

IMPORTANT NOTES:
1)
This manual is valid for the following Model and associated serial numbers:
MODEL
SERIAL NO.
REV. NO.
2)
A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your
particular model and serial number.
3)
The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc.
Data subject to change without notice.
KEPCO
®
THE POWER SUPPLIER™
MODEL
OPERATOR’S MANUAL
KEPCO INC.
KEPCO, INC. z 131-38 SANFORD AVENUE z FLUSHING, NY. 11355 U.S.A. z TEL (718) 461-7000 z FAX (718) 767-1102
email: [email protected] z World Wide Web: http://www.kepcopower.com
An ISO 9001 Company.
©2012, KEPCO, INC
P/N 243-0850b
HSM SERIES
1000 AND 1500 WATT SWITCHING POWER SUPPLY
VOLTAGE/CURRENT-STABILIZED DC SOURCE
HSM SERIES
POWER SUPPLY
Document Outline
- SECTION I - INTRODUCTION
- 1.1 Scope of Manual
- 1.2 General Description
- 1.3 Specifications
- 1.4 Miscellaneous Features
- 1.4.1 Control/programming
- 1.4.2 Status Flags:
- 1.4.3 Setpoint Monitors:
- 1.4.4 Remote Error Sensing:
- 1.4.5 Load Sharing:
- 1.4.6 Load Monitor:
- 1.4.7 Auxiliary Supply:
- 1.4.8 Overcurrent/undervoltage Protection:
- 1.4.9 Current Walk-in:
- 1.4.10 Remote Reset:
- 1.5 Options
- 1.5.1 Battery Charger (B Suffix):
- 1.6 Accessories
- SECTION 2 - INSTALLATION
- 2.1 Unpacking and Inspection
- 2.2 Terminations and Controls
- 2.3 Source Power Requirements
- 2.4 Cooling
- 2.5 Preliminary Operational Check
- 2.6 Installation
- 2.7 Wiring Instructions
- 2.7.1 Safety Grounding
- 2.7.2 Source Power Connections
- 2.7.3 D-C Output Grounding
- 2.7.4 Power Supply/Load Interface
- 2.7.5 Load Connection - General
- 2.7.5.1 Load Connection - Method I (Local Error Sensing)
- 2.7.5.2 Load Connection - Method II (Remote Error Sensing)
- 2.7.5.3 Load Connection - Method III (Series Connection)
- 2.7.5.4 Load Connection - Method IV (Parallel/Redundant Operation)
- 2.7.6 Load Sharing
- 2.7.7 Signal Connections
- SECTION 3 - OPERATING INSTRUCTIONS
- 3.1 Operating Configuration
- 3.2 Remote Error Sense
- 3.3 Output Voltage Programming
- 3.4 Output Voltage Range
- 3.5 Current Limit Programming
- 3.6 Current Limit Programming Range
- 3.7 Setpoint Monitors
- 3.8 Overvoltage Protection Adjustment
- 3.9 Current Limit Characteristic
- 3.10 Current Walk-in Circuit
- 3.11 5VAUX Floating Supply
- 3.12 Remote Inhibit/Remote Reset Controls
- 3.13 Module Current Monitor
- 3.14 Status Flags
- 3.14.1 Source Power Status Flags
- 3.14.2 OUTPUT Status Flags
- 3.14.3 OVERTEMP Status Flags
- 3.14.4 FANFAIL Status Flags