Rs-232c protocol, Parameters of the rs-232c protocol, Rs-232c protocol -7 – TA Triumph-Adler LP 4140 User Manual
Page 157

Computer Interface
ADVANCED OPERATION GUIDE
5-7
RS-232C Protocol
Parameters of the RS-232C Protocol
A protocol is a set of rules the computer follows in sending data to the
printer. They are indicated on the status page. Parameters can be changed
from the operation panel. Refer to Changing Serial Interface Modes on
page 2-36. The parameters and their identification codes are given below.
•
H1: Baud rate
•
H2: Number of data bits
•
H3: Number of stop bits
•
H4: Parity
•
H5: Protocol logic
•
H6: Buffer-nearly-full threshold
•
H7: Buffer nearly-empty threshold
•
H8: Received data buffer size
This following section outlines the parameters and their values you can
select on the operation panel:
H1: Baud rate
The factory default setting is 9600 baud.
H2: Data bits
7 or 8; the factory default setting is 8.
H3: Stop bits
1 or 2; the factory default setting is 1.
Parameter value
Baud rate
12
1200
24
2400
48
4800
96
9600
19
19200
38
38400
57
57600
11
115200