TA Triumph-Adler LP 4140 User Manual
Page 154

Computer Interface
5-4
ADVANCED OPERATION GUIDE
*
Indicates signals that are low active.
** The Paper Empty, Online, and Error signals work only after you have enabled them using the O2
parameter of the FRPO command.
10
Out
Acknowledge* [nAck]
This negative-going pulse acknowledges the previous
character received.
11
Out
Busy [Busy]
When this signal is high, the printer is busy. When it is low,
the printer is able to receive more data.
12
Out
Paper Empty
[PError]
This signal goes high when the printer runs out of paper.**
13
Out
Online (Select) [Select]
This signal goes high when the printer is online and low
when the printer is offline. The signal goes low when you
press [GO] to make the printer go off line.**
14
In
— [nAutoFd]
Ignored
15
—
—
Not used
16
—
0 V DC
17
—
Chassis Ground
18
—
+5 V DC
This pin is used for the printer’s +5 V DC power supply
(+5±0.5 V, 400 mA maximum, with fuse)
19
—
Ground return
20
—
Ground return
21
—
Ground return
22
—
Ground return
23
—
Ground return
24
—
Ground return
25
—
Ground return
26
—
Ground return
27
—
Ground return
28
—
Ground return
29
—
Ground return
30
—
Ground return
31
In
— [nInit]
Ignored
32
Out
Error* [nFault]
When the high-speed parallel line control is on, this line
returns an error status.**
33
—
—
Not used
34
—
—
Not used
35
Out
Power Ready
This signal goes high when the printer is powered on.
36
In
Select In [nSelect In]
When this line is high, IEEE1284 mode is enabled.
Pin
In or
out
Signal
Description