QuadraVista QF Installation and Operations Manual
45
containing the defined elements like switching to a given port, changing the display mode, defining the PiP
features, and other items.
To use the DCP/XML feature, connect the system in the serial configuration as shown in
Figure 36. The PC or laptop must have a serial communication program installed like HyperTerminal.
Configure the communication program for the following:
•
Transfer rate – 57600 Baud
•
Data Bits – 8
•
No parity
•
Stop Bit – 1
•
No flow control
Connect to QuadraVista and send the DCP/XML text message containing the controlling script. A simple
example of sending a DCP/XML text message that will switch ports is shown below.
Tabbed spacing in the below example is for readability only; the actual text file does not need the spacing.
This example switches the console and video to channel 0
Note: DCP/XML channel 0 = QuadraVista channel 1
DCP/XML channel 1 = QuadraVista channel 2
DCP/XML channel 2 = QuadraVista channel 3
DCP/XML channel 3 = QuadraVista channel 4
An example of a DCP/XML message containing all defined elements is shown below: