Chapter 8 analog i/o – Remote Processing RPC-2300 User Manual
Page 27
CHAPTER 8
ANALOG I/O
RPC-2300
Page 25
0 - 10
value= V * 409.5
± 5V
value= V * 409.5 + 2047.5
The result of the formula produces a number which can
be used in place of value.
COMMANDS
The following is a list of CAMBASIC II com mands for
analog input an d output.
Comm and
Function
CON FIG AIN
Configures analog input
AIN
Returns result of reading
AOT
Sends number to D/A converter