MCZ Comfort Air SLIM User Manual
Page 27

SLIM-BASIC COMFORT AIR KIT
Chapter 3
USE AND MAINTENANCE MANUAL
page
27
Basic comfort air kit
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited
SONDA (NTC)
2.5.2.1.
Fitting the temperature sensor for automatic
operation
The sensor is supplied as standard with the control unit and the remote
control.
The temperature sensor must be connected to the control unit and
sensitive parts (A-B), to the conveyor (1) (see diagram below).
Proceed as follows to fit it:
Remove the aluminised tape from the motor to gain access to
the sensor insertion and fastening holes
Insert the metal terminal “A” into the hole in the motor and
secure the flange “B” with a self-tapping screw
Insert the terminals of the sensor cable “C” into the control
unit terminal
A
B
C
SENSOR
INSERTION
HOLE (A)
SENSOR
FASTENING
HOLE (B)
CABLE TERMINAL
(C) TO BE
INSERTED INTO
THE CONTROL
UNIT
MOTOR
DETAIL
SENSOR (NTC)
1