MCZ Comfort Air SLIM User Manual
Page 19

SLIM-BASIC COMFORT AIR KIT
Chapter 3
USE AND MAINTENANCE MANUAL
page
19
Basic comfort air kit
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited
GHOST lamp insertion
As mentioned in paragraph 2.2.3, for this type of hot air outlet, only ducting to the left or right is possible. The
glass insertion mechanism is the same as for the Flip and Float lamps.
The actuator with the extension - used to open the lamp glass - is fitted onto the hot air outlet support for the
Ghost lamp. The actuator must always be seated at the top, so if the support is turned, the actuator and
the extension need to be moved to the top hole.
Consequently, for this type of hot air outlet, you need to envisage the electrical connection for the actuator as
well, according to the wiring diagram shown above.
In the GHOST hot air outlet, only a single lamp holder with a lamp can be installed at the bottom, where the
lamp glass lifts up.
IMPORTANT!
The cable to connect the lamp/fan is made of silicone
to withstand high temperatures. If the cable is
extended (to more than 2.5 m) and in any case always
make sure the cable does not touch hot parts of the
unit, or air connection pipes inside the cladding or
structure.
ACTUATOR
W/EXTENSION
LAMP HOLDER+LAMP – TO
BE FITTED AT THE
BOTTOM
GHOST