MCZ Comfort Air SLIM User Manual
Page 25

SLIM-BASIC COMFORT AIR KIT
Chapter 3
USE AND MAINTENANCE MANUAL
page
25
Basic comfort air kit
Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited
SONDA
NEUTRO (Neutro/Blu)
FASE (Neutro/Marrone)
FASE ATTUATORI
(Bianco)
FASE VENTILATORI
(Nero)
FASE LAMPADE
(Blu)
SONDA (NTC)
SCATOLA DI
DERIVAZIONE
2.3.3.
Connecting the electronic control unit
The control unit is supplied with faston connectors to connect:
1. 230V power supply (N)
2. 230V power supply (L)
3. Glass actuator (UNL)
4. Fans (FAN)
5. Light (LAMP)
It is also fitted with a screw terminal to connect the temperature sensor
(6).
Arrange an insulated junction box in which to make connections to the
line according to the diagram shown in the figure.
Connect the phase of fans 1 and 2 to the FAN terminal on the control
unit.
Connect the phase of the lamps to the LAMP terminal on the control
unit.
Connect the actuator phase (when envisaged in the hot air outlet) to
the UNL terminal on the control unit.
Connect the power supply cable of the control unit (L N).
Connect the temperature sensor (if you want automatic operation) to
the screw terminal.
Secure the electronic control unit to the recessed box using the screws
provided, then power the appliance.
JUNCTION
BOX
SENSOR (NTC)
SENSOR
LAMP PHASE (Blue)
FAN PHASE (Black)
NEUTRAL (neutral/Blue
)
PHASE (neutral/Brown)
ACTUATOR PHASE
(White)