Pressure Systems 9022 User Manual
Page 94

Pressure Systems, Inc.
NetScanner™ System (9016, 9021, & 9022) User’s Manual
cc
Transducer Coefficient Description
Datum
Type
www.PressureSystems.com
3 - 64
24-28
Temperature 6, Pressures 1-5 voltages
FLOAT
29-2D
reserved for future use (temperature 7)
FLOAT
2E
Te mpe rature 1 Te mpe rature O utput vo ltage at 0 psi
FLOAT
2F
Tem perature 2 Tem perature O utput voltage at 0 p si
FLOAT
30
Tem perature 3 Tem perature O utput voltage at 0 p si
FLOAT
31
Tem perature 4 Tem perature O utput voltage at 0 p si
FLOAT
32
Tem perature 5 Tem perature O utput voltage at 0 p si
FLOAT
33
Tem perature 6 Tem perature O utput voltage at 0 p si
FLOAT
34
(reserved) T empe rature 7 T empe rature Ou tput voltage at 0 psi
FLOAT
35
Temp Vs Pressure Correction coefficient (t0)
FLOAT
36
Temp Vs Pressure Correction coefficient (t1)
FLOAT
37
Temp Vs Pressure Correction coefficient (t2)
FLOAT
38
Temp Vs Pressure Correction coefficient (t3)
FLOAT
4D
Pressure Voltage Gain Index
Integer
4E
Temperature Voltage Gain Index
Integer
5F
Current Calculated Pressure (PSI)
FLOAT
The User Defined Date field (cc=07) is also a 32-bit integer which may be encoded
in a similar manner. Possible uses are to indicate the date of last user zero and/or
span calibration or possibly the date of next required calibration. If this optional
field is used, the user is responsible for correctly encoding the date into the
appropriate 32-bit integer value. Any modifications of this field (using the
Download Internal Coefficients (‘v’) command) will result in the new value
automatically being entered to transducer non-volatile memory.
The Date of Factory Calibration field (cc=08) identifies the date of factory
calibration for the DH200 transducer (9016) or 9400 transducer (9021/9022. It is
stored internally as a 32-bit integer whose value (viewed as a decimal number) is in
the format of yymmdd (year, month, day).