NetScanner™ System (9016, 9021, & 9022) User’s Manual

ii

dd

Description

‘q’ read

index

www.PressureSystems.com

3 - 73

26

00

01

(for Models 9021 and 9022 ONLY) Initialize Generic
Sensor Parameters with Factory Default Parameters on
Power-up
.
Retrieve user-provided parameters out of non-volatile
memory

27

00

Store current coefficient terms into transducer’s non-
volatile memory. (For use only with non-digitally
compensated 9400 sensors with EEPROM.) (‘w27’ selects
all channels) (‘w2700 eeee’ selects individual channels via
the position field)

3C

00

(9016 only) Set Temperature Range = 0 to 60ºC default

06

Set Temperature Range = -30 to 60ºC

07

Set Temperature Range = -20 to 70C

Modification of option 13 hex results in the new option selection becoming the module’s new
power-on default. All other options must be stored in non-volatile flash memory using ‘w07
command in order to be retained after the module power cycles.