Fig.2 rubber cone dimensions – Sealey VS870 User Manual
Page 3

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPortant: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
inforMation: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk Business
Park
, Bury st. edmunds, suffolk,
iP32 7Ar
Original Language Version
Vs870 issue: 1 - 02/11/12
01284 757500
01284 703534
www.sealey.co.uk
Web
Environmental Protection.
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging
should be sorted, taken to a recycle centre and disposed of in a manner which is
compatible
with
the
environment.
When the product is no longer required, it must be disposed of in an environmentally protective way.
Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to
www.sealey.co.uk, email [email protected] or phone 01284 757500.
© Jack sealey ltd
4.1
If the amount of smoke generated reduces over time, it may indicate that the fibreglass element/wick
needs replacement.
4.2
The fibreglass element is considered to be a consumable item. The part number for the replacement is:
Vs870.01
4.3
Fibreglass Element/Wick Replacement.
4.3.1 Soak replacement fibreglass element/wick in mineral (baby) oil before starting proceedure.
4.3.2 Remove oil filler plug (take care not to tilt machine and spill oil).
4.3.3 remove the 5 screws securing the top cover, and remove it.
4.3.4 remove the vaporiser housing by taking out the 3 4mm hex bolts around its base and laying it to one side.
(see fig.3).
4.3.5 This will expose the element which can be removed by unscrewing the securing screws (A &B in fig.4).
4.3.6 fitting the replacent element is the reverse of 4.3.2 to 4.3.5 above. care should be taken not to damage
the Rubber 'O' Ring within the base of the vapouriser housing (see fig.5) when replacing.
4. Maintenance
fig.2
fig.4
fig.5
fig.3
fig.2
Rubber Cone Dimensions