beautypg.com

Environmental protection – Sealey VS0052 User Manual

Page 2

background image

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

© Jack sealey Limited 2013

Vs0052 Issue: 1 - 11/03/13

8.1. Keep unit clean. Protect eye lens, display lid and prism to prevent scratching.

8.2. for best results an ambient temperature of 20°c for both refractometer and fluid being tested is recommended.

8.3. To test instrument accuracy, place distilled water on the prism and check that the LIGHT-DARK dividing line is

level with the “WAtErLInE”. If the reading is incorrect remove the black rubber cover from the calibration point

(6). Insert the small supplied screwdriver into the hole in the calibration point. Turn the screwdriver whilst

looking through the eyepiece until the waterline mark is on the light-dark dividing line.

8.4. After use and cleaning store in supplied foam lined and plastic case.

7.1. read the test procedure.

7.2. refer to Scale D which Indicates the percentage of urea to distilled water in AdBlu; 32.5 indicates the most

desirable percentage of urea in the solution.

4. ANTIFREEZE TEST

4.1. read the test procedure.

4.2. For “Propylene Glycol” read the left side of Scale A. for “Ethylene” read the right side of Scale A.

5. WINDSCREEN WASHER

5.1. read the test procedure

5.2. refer to Scale B. note: Variations in formulation of windscreen washer fluids may result in an average value

for a variety of alcohol based anti-freeze mixtures, this test is therefore a guideline only.

6. BATTERY FLUID TEST

6.1. read the test procedure.

6.2. refer to Scale C which Indicates the density of the battery fluid in kg per litre and the ranges for Recharge,

Fair and Good.

7. ADBLU TEST

8. MAINTENANCE / CALIBRATION