3.2.3. Press buttons to select the battery type
SLI or SEAL:
SLI: Standard SLI flooded batteries.
SEAL: VRLA/GEL/AGM etc. sealed/mF batteries.
3.2.4
Press enter for the next step.
3.2.5
Press key to select the battery rating:
SAE, DIN, IEC, En or CA (mcA).
3.2.6
Press enter for the next step.
3.2.7
Press key to input the battery capacity of ccA or cA(mcA) sAE.
200-1200 ccA DIn, 110-670 ccA IEc, 130-790 ccA En, 185-1125 ccA cA(mcA), 240-1440 cA(mcA). Press
ENTER to begin test.
3.2.8
Test the battery within 1 second.
3.2.9
If
CHA- is displayed (is battery charged?) press ENTER and select key to choose YES or NO, then press ENTER for the next step.
(bT2101 will determine the tested battery status and if acceptable will not show step 3.2.9).
3.2.10. When the test is complete the display will show the actual voltage, then the actual ccA and then one of the following messages:
PASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . battery OK and ready for use. ‘Pass’ lED will be illuminated.
PASS & CHAR . . . . . . . . . .battery OK but needs recharging. ‘Pass’ and ‘Recharge’ lEDs will be illuminated.
CHAR & TEST . . . . . . . . . . . . . . . . . . . Recharge battery and then retest. ‘Recharge’ lED will be illuminated.
FAIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . battery will not hold charge - replace. ‘Fail’ lED will be illuminated.
BAD CELL . . . . . . . . . . . . . . . . . . . . . . . . . . . battery has faulty cell(s) - replace. ‘Fail’ lED will be illuminated.
ERR. (LOAD ERROR) The tested battery is bigger than 1200ccA or 120AH. Or the clamps are not connected properly. Please fully charge the battery
and retest after excluding both previous reasons. If the reading is the same, the battery should be replaced immediately.
3.2.11 Press EnTER button to return to start of test sequence or remove the clamps from the battery if no further tests required.
4. TROUBLESHOOTING
TROUBLESHOOTING:
If the screen shows ‘HI’:
Voltage of the tested battery is over 15.00V & too high for 12V battery. bT2101 won't work under this situation. Please re-check if the tested battery is 12Volts.
Voltage of the tested battery is under 1.5 Volts. bT2101 won't work under this situation. Please recharge the battery & retest. If reading is the same, the
battery should be replaced immediately.
If the screen shows blank:
The voltage of the tested battery is too low to serve the bT2101. Please recharge the battery and retest. If reading is the same, the battery should be replaced
immediately. Or the clamps are connected to incorrect polarity. Please check & re-connect (red clamp to the positive (+) battery terminal and the black clamp
to the negative (-) terminal).
The screen flickers or shows ---- :
The voltage is unstable. A just completely charged battery or other factors can cause the battery's voltage to be unstable, the lED display shows "-----".
Please wait for 15-30 minutes to let the battery voltage stabilize & test the battery or eliminate the factors to test the battery.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk business Park
,
bury st. Edmunds, suffolk,
IP32 7AR
www.sealey.co.uk
Web
Original Language Version
bT2101 Issue: 6 - 17/11/11