Page 2

background image

3. RIG OPERATION

4.1.9 rear lasers should align with the calibration line on the rear

flags.

4.1.10 If front or rear Lasers are not aligned the units need to be

recalibrated.

4.2 Calibration

4.2.1 remove the protective laser calibration guard on the laser

that needs to be adjusted.

4.2.2 slacken the two allen nuts on the laser that needs adjusting.

see figs. 3 & 4.

4.2.3 turn on the laser.

4.2.4 Adjust laser to the correct position by moving the slotted fixing

up or down the slot as required. When the laser light strikes the

zero toe mark or the calibration line on the rear flags tighten

the two allen nuts and replace the protective covers

4.2.5 check ALL lasers are aligned correctly.

4.3 GA70CR – Calibration Rig yearly/periodic inspection

4.3.1 Mearsure/check the distance between the two front and two

rear calibration contact points to make sure the measurement

are the same.

4.3.2 rear flags - Measure distance from the frame and the vertical

calibration lines. Both measurement must be the same.

4.4 GA70CAL

4.3.1 We also offer a calibration service at sEALEY where we will

check/calibrate the customers GA70 unit.

fig.2

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, suffolk Business

Park

, Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email

[email protected] or phone 01284 757500.

GA70cr Issue: 1 - 05/05/11

Original Language Version

fig.3

fig.4

4.1 GA70 Calibration Check

4.1.1 Visually inspect the laser units to make sure they are not

damaged or bent. A damaged Laser Head may not calibrate

correctly.

4.1.2 remove the 6 nuts from the threaded ends of the 6 mounting

pillars (1 at the top and two at the bottom on each side) see

fig.1-1.

4.1.3 Adjust the height of each laser unit to match the mounting

pillars using the black knob on each unit. see fig.2-B. Move

the three wheel rim locators to the outside end of their

respective slots.

4.1.4 fit the two laser alignment units onto the pillars and secure

them hand tight using the nuts previously removed. see fig.2.

4.1.5 on each side of the rig adjust the position of the three wheel

rim locators onto the rig alignment pads (see fig.2 InsEt 'A')

4.1.6 Make any necessary fine adjustments then turn on the Lasers.

Manoeuvre one of the laser Heads backwards/forwards so the

Lasers read as near to Zero as possible.

4.1.7 tighten the 6 holding nuts.

4.1.8 front Lasers should read Zero using the correct calculation.

observe where the laser line falls on each toe scale. Either

both lasers will be pointing to Zero which is correct, or, one

laser will read in the rED and one laser will read in the

GrEEn. In this case subtract one from the other and the

reading should be Zero. for example, 1 rED minus 1 Green

equals ZEro (calibration is correct). If the reading is not Zero,

calibration is required.