beautypg.com

Declaration of conformity, Fig.3a, Fig.2 fig.3b – Sealey HFC08 User Manual

Page 2

background image

01284 757500

01284 703534

[email protected]

Sole UK distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Web

email

notE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPoRTANT: No liability is accepted for incorrect use of this product.

WARRANTy: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFoRMATIoN: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

declaration of Conformity

We, the sole importer into the UK, declare that the product listed below is in conformity with the

following standards and directives.

The construction file for this product is held by the Manufacturer and may be inspected, by a

national authority, upon request to Jack Sealey Ltd.

For Jack Sealey Ltd. Sole importer into the UK of Sealey Professional Tools.

25th June 2009

Signed by Mark Sweetman

oil Filter Crusher

Model No. HFC08.V2

93/68/EEC CE Marking Directive

2006/42/EC Machinery Directive

5. MAINTENANCE

4. oPERATIoN

WarnInG! all inspection and maintenance procedures should be carried out with the air disconnected and the ram retracted.

5.1 Normal maintenance.

5.1.1 Persons using the crusher should be properly trained in its use including inspection of the unit prior to operation. If the operator is in any

doubt regarding the proper functioning or structural integrity of the unit it should not be used. Remove it from service immediately and

contact your local Sealey dealer.

5.1.2 If the unit is used daily it should be further inspected by a qualified person on a weekly basis.

5.1.3 If the unit is used intermittently it should be further inspected by a qualified person on a monthly basis.

5.1.4 All warning labels, instruction labels, and specification labels should be complete and readable.

5.1.5 External surfaces of the unit can be washed with a mild soap solution.

5.1.6 Clean and/or remove sludge and other foreign matter from the crushing chamber after each use.

HFC08.V2 Issue: 1 - 25/06/09

3.3 Fitting door Handle.

Place the handle shaft through the door from the outside and secure with

nylon washer and nut (Fig.3a).

Note: The door handle has a locking button and when fitting the handle it

should be configured so the locking button requires pressing to fully latch

or unlatch the door. The handle should be configured so the closed

(locked) position will leave the handle pointing downwards.

3.3.1

Move the handle to the horizontal (open) position. place the washer and

door catch on the end of the door handle shaft pointing downwards and

secure with the screw (Fig.3b).

Wave Washer

Domed Washer

Screw

Fig.3a

Nut

Nylon Washer

4.1

Open air regulator and set pressure to a minimum of 100psi.

4.2

Place the empty filter, open end downwards in the centre of the crushing chamber.

4.3

Close the door ensuring the lock is full engaged. (The crusher will not function until the door is firmly closed).

4.4

Turn the control lever LEFT to the 'DOWN' position and the piston will descend.

4.5

When the crushing ram reaches the bottom the filter is crushed. You can also listen for the air to stop flowing (approx 30 seconds).

4.6

Turn the control lever RIGHT to the 'UP' position, when the piston has returned to the start position move the control lever back to the

centre 'STOP' position.

WarnInG! never attempt to open the door until the piston is fully retracted and the control lever is in the 'Stop' position.

4.7

Open the door and remove the crushed filter. Close air regulator and disconnect air supply.

Note: Leave the door ajar when not in use.

3.2. Air Supply.

Connect the air supply to the air inlet on the air regulatoe mounted on the

right hand side of the unit adjacent to the door handle. The inlet connection

is 1/4”FNPT.

The recommended air hook-up procedure is shown in Fig.2

3.2.1 You will require a minimum air pressure of 100psi.

3.2.2

WARNING! Ensure the air supply is clean and does not exceed 190psi whilst

operating the filter crusher. Too high an air pressure and unclean air will

shorten the product life, and may be dangerous, causing damage and/or

personal injury.

3.2.3 Drain the air tank daily. Water in the air line will damage the ram.

3.2.4 Clean compressor air inlet filter weekly.

3.2.5 Line pressure should be increased to compensate for unusually long air hoses (over 8 metres).

3.2.6 Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure.

Fig.2