1. Turning the tool on / off (see figs 1 & 2)

4.1.1. Press button to turn on. The buzzer sounds and on the display shows all the readouts simultaneously. After 3 seconds the display

shows “ 0000 ” on the screen.

4.1.2. Under torque measuring mode, press button again to turn the electronic system off.

4.1.3. The screwdriver will turn off automatically without any buttons being pressed, or inactivity over 2 minutes.

4.2. Check battery charge level indicator:

If the battery is empty, the indicator on the display will show ,an entirely white battery symbol. The batteries must be replaced in

order to guarantee full function and accuracy.

4.3. Activating the Track Mode:

4.3.1. After turning on the display, the default is in “Peak” mode, the maximum value reached will be saved additionally and the value is shown

on the display for approx. 2 seconds. After that, this value flashes and then you can continue to the next application or press button to

zero.

4.3.2. During the “Track” mode, the real-time torque reached during operation will be displayed.

4.3.3. To select either “Track” or “Peak” mode, first press: and, within 3 seconds: .

4.4. Unit Selection:

With the unit switched on, press and hold for 5 seconds to switch between Nm and lb/ft.

4.5. Programming the Pre-set Torque Value.

4.5.1. Press and hold the button for 3 seconds to enter the setting mode. Release the button when “

SEt” is shown on the screen.

4.5.2. Press button to increase the pre-set torque. Note: In the setting mode, the display will

NOT show peak on the left side of the screen.

4.5.3. To increase the value, keep the button pressed to increase the rate of increase.

4.5.4. To decrease the value, press to zero the display, then press to increase to the required value.

4.5.5. Once the target torque has been selected, the screwdriver will memorise that torque after 3 seconds.

4.5.6. If a target torque of more than 100% maximum torque value(5Nm)is selected, the display will zero and no setting will be entered.

5.1. After applied force, the maximum value reached will be saved additionally and the value is shown on the display for approx. 2 seconds. If

the target torque is reached,the buzzer will sound, the LED indicator will light and the handle will vibrate for approx. 2 seconds.

5.2. This value will continue flashing allowing the reading to be used for the next application. Alternatively, the button may be pressed to

zero the reading before the next application.

5.3. When force is applied in an anticlockwise direction, the display will show a minus (-) sign on the left side of screen. The following reading

will be positive when clockwise torque is applied.

5.4. The meter will switch off automatically after approx. 2 minutes of inactivity.

CAUTION: DO NOT use the screwdriver when the battery level is low. An inaccurate reading is possible in this condition.

6.1. DO NOT apply force when the power is turned off.

6.2. DO NOT expose the unit to strong magnetic fields, corrosive agents, excessive heat or humidity.

6.3. Clean only with a damp cloth, do not use proprietary cleaners or solvents to clean this product.

6.4. If it is anticipated that the screwdriver will be out of use for a time, the batteries should be removed (fig.2).

6.5. When not in use, store in a cool, dry location away from direct sunlight and out of the reach of children.

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging

should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable) into

approved containers and dispose of the product and the fluids according to local regulations.

WEEE Regulations

Dispose of this product at the end of its working life in compliance with the EU Directive on

Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed

of in an environmentally protective way. Contact your local solid waste authority for recycling information.

Battery Removal

For battery removal, see fig.2.

Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential

purchasers of products containing batteries (as defined within these regulations), that they are registered with

Valpak’s registered compliance scheme. Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is

BPRN00705.

Parts support is available for this product. To obtain a parts listing and/or diagram,

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Original Language Version

© Jack Sealey Limited

STS103 Issue: 1 01/05/14

5. OPERATION

6. CARE

4. SETTING