background image

Original Language Version

4.1.

When the jack is not in use, the ram and the handle socket

should be in their lowest positions to minimise corrosion.

Remove the handle to deactivate the jack.

4.2.

Keep the jack clean and lubricate all moving parts on a

regular basis, pump grease into the grease nipple (fig.2).

4.3.

Before each use, check for broken, cracked, bent, or loose

parts, or any visible damage to ram, pump, saddle, lifting

arm, frame and all parts including nuts, bolts, pins and other

fasteners. If any suspect item is found remove jack from

service and take necessary action to remedy the problem.

do not use the jack if believed to have been subjected to

abnormal load or shock load.

4.4.

Periodically check the pump piston and piston rod for signs

of corrosion. Clean exposed areas with a clean oiled cloth.

4.5.

After one year the oil should be replaced in order to extend

the life of the jack. Use hydraulic jack oil only.

3

I

mportant: Only fully qualified personnel should attempt

hydraulic maintenance or repair.

4.6.

To check the hydraulic oil level, fully lower the jack and the

handle and remove the oil filler plug

(fig.2). The correct oil

level should be approximately 5mm below the filler opening.

If oil level is low, fill as required. Make sure that dirt is not

allowed to enter the hydraulic system. Carefully pump unloaded

jack 5 or 6 times to expel any air and then refit oil filler plug.

note: Use a good quality hydraulic jack oil, such as SEALEY

HYDRAULIC JACK OIL.

p

WaRninG: Do not use brake fluid, or any fluid other than

hydraulic jack oil, as this may cause serious damage to the

jack and will invalidate the warranty!

3

iMPoRtant: no ResPonsiBility is accePted foR

incoRRect use of this PRoduct.

Hydraulic products are only repaired by local service agents.

We have service/repair agents in all parts of the UK.

Do not return jacks to us. Please telephone us on

01284 757500 to obtain the address and phone number of

your local agent. If jack is under guarantee contact your local

Sealey dealer.

de-commissioning the Jack

Should the jack become completely unserviceable and require

disposal, draw off the oil into an approved container and

dispose of the jack and the oil according to local regulations.

4. Maintenance

5. tRouBle shootinG

3010CX ISSUE No:1 - 23/12/09

notE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPoRtant: No liability is accepted for incorrect use of this product.

WaRRanty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

infoRMation: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

sole uk distributor, sealey Group,

Kempson Way, Suffolk Business

Park

, Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

PROBLEM

POSSIBLE CAUSE

REMEDY

Jack will not lift

the load

Jack does not lift

high enough or

feels “spongy”

Jack lifts poorly

Jack lifts but will

not hold load

Jack will not lower

completely

Jack does not

lower at all

1)

Be sure to use jack with adequate capacity

2)

Top up oil level

3)

Check and close release valve

4)

Open release valve and pump the handle a few times. Close valve and re-try

5)

Clean and replace oil

6)

Replace packing

1)

Top up oil level or remove excess oil

2)

Return jack to local service agent

3)

Open release valve and pump the handle a few times. Close valve and re-try

4)

Check and close release valve

1)

Replace packing and/or clean valves

2)

Replace oil

3)

Open release valve and pump the handle a few times. Close valve and re-try

1)

Check and close release valve

2)

Lower jack, close release valve. Place foot on front wheel and pull up lifting arm to it's full height by hand

Open the release valve to lower arm

3)

Open release valve and pump the handle a few times. Close valve and re-try

4)

Replace packing or contact local service agent

5)

Replace packing

1)

Oil all external moving parts

2)

Replace rod or contact local service agent

3)

Replace damaged parts or contact local service agent

4)

Open release valve and pump the handle a few times. Close valve and re-try

5)

Check and fully open release valve

6)

Replace spring or contact local service agent

1)

Check and fully open release valve

1)

Overloaded

2)

Oil level low

3)

Release valve not correctly closed

4)

Air in system

5)

Piston rod not functioning

6)

Packing worn or defective

1)

Oil level too high or too low

2)

Worn seals

3)

Air in system

4)

Release valve not closed

1)

Pump packing or valves malfunctioning

2)

Oil is dirty

3)

Air in the system

1)

Release valve partially open

2)

Dirt on valve seats

3)

Air in system

4)

Faulty seals

5)

Packing worn or defective

1)

Unit requires lubrication

2)

Piston rod bent or damaged

3)

Jack frame/link system distorted due

to overloading/poor positioning

4)

Air in system

5)

Release valve partially open

6)

Jack spring damaged

1)

Release valve still closed

fig.2