7. TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

REMEDY

Vehicle does not lift but pump is OK

1. Oil exhausted.

1. Supply oil.

2. Air in hydraulic system.

2. Purge the hydraulic circuit..

3. Defective suction or delivery valves.

3. Clean clogged valve.

4. Defective packing or 0-ring.

4. Replace.

5. Poor oil quality.

5. Replace oil.

Air pump does not operate.

1. Insufficient compressor power.

1. Use a compressor larger than 3HP.

2. Pump oil used up.

2. Dismantle the air pump and coat it with soft quality non

acid grease or lubricate air valve.

Vehicle stops before lift is completed.

1. Hydraulic oil is insufficient.

1. Supply oil.

Jack lowers or does not hold vehicle

in the raised position.

1. Defective suction, delivery, release or

safety valve.

1. Clean and adjust valve.

2. Defective piston packing.

2. Replace packing.

Lifting is too slow

1. Air leakage due to worn servo-valve.

1. Replace servo-valve.

Pump continues to operate when the

air valve is closed.

1. Air valve will not close.

1. Replace valve.

IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE MACHINE.

Air / Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.

DO NOT return jacks to us. Please telephone us on 01284 757500 to obtain the address and phone number of your local agent. If the jack

is under guarantee please contact your dealer.

Decommissioning the jack

Should the Jack become completely unserviceable and require disposal, draw off the oil into an approved container and dispose of the jack

and the oil according to local regulations.

IMPORTANT: Only fully qualified personnel should attempt maintenance or repair.

WARNING! Disconnect jack from air supply before changing parts, servicing or performing any maintenance.

7.1. When the jack is not in use, the piston rod must be in the lowest position to minimise corrosion.
7.2. Confirm that the piston can rise to the highest position before use.

7.3. If the air system does not have an oiler, lubricate the air pump once or twice a month with a few drops of Sealey air tool oil dripped into

the air inlet to prolong air pump life.

7.4. After extensive use, the oil should be replaced in order to extend the life of your equipment.

This procedure should be undertaken by

a hydraulic repair specialist. The capacity of the reservoir is .72ltr; only a good quality hydraulic jack oil such as Seeley Jack Oil

should be used.

7.5. Check the piston rod periodically for signs of corrosion. Clean exposed areas with a clean oiled cloth.

7. MAINTENANCE

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk,

email [email protected] or telephone 01284 757500.

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling

centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires

disposal, drain off any fluids (if applicable) into approved containers and dispose of the product and the fluids according to local regulations.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

YAJ201 Issue: 1 -08/12/14

© Jack Sealey Limited

This manual is related to the following products: