notE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTanT: No liability is accepted for incorrect use of this product.

WaRRanTy: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

InfORMaTIOn: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole uK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

Important: no rESponSIBILItY IS aCCEptED For InCorrECt USE oF tHE maCHInE.

Air / Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.

Do not rEtUrn jaCkS to US.

Please telephone us on 01284 757500 to obtain the address and phone number of your local agent. If jack is under guarantee please contact your dealer.

De-commissioning the Jack

Should the jack become completely unserviceable and require disposal, draw off the oil into an approved container and dispose of the jack and the oil according to

local regulations.

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk,

email [email protected] or phone 01284 757500.

YAJ301,YAJ10-25LR,YAJ15-30LE Issue 1-29/04/13

YAJ20-60LR, YAJ10-40LELR

© Jack Sealey Limited

Environmental Protection.

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken

to a recycling centre and disposed of in a manner which is compatible with the environment.

8. TROuBLEShOOTInG

PROBLEM

POSSIBLE CauSE

REMEDy

Jack does not lift but pump is working.

1. Oil exhausted.

2. Air in hydraulic system.

3. Defective suction or delivery valves.

4. Defective packing or O-ring.

5. Poor quality oil.

1. Supply oil.

2. Drain air by opening cap plug of suction

and delivery valves.

3. Clean clogged valve.

4. Replace.

5. Replace oil.

Air pump does not operate.

1. Insufficient compressor power.

2. Pump oil used up.

1. Use a larger compressor.

2. Find leak and rectify, refill with oil.

Rebuild and lubricate air valve.

Jack stops before end of travel.

1. Hydraulic oil is insufficient.

1. Replenish oil.

Jack lowers or does not hold in the raised

position.

1. Defective suction delivery, release or

safety valve.

2. Defective piston packing.

1. Clean and adjust valve.

2. Replace packing.

Lifting is slow.

1. Air leakage due to worn servo-valve.

1. Replace servo-valve.

Pump continues to operate when the air valves

are closed

1. Air valve will not close.

1. Replace Valve.