the sM47.V3 is designed to extract dust, saw dust and other fine

debris from wood machining. It

should not be used to extract

metallic debris, glass or water.

2. APPLICATION & SPECIFICATION

capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700cfm

Impeller diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250mm

collector hose diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125mm

Intake hose diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 100mm

Intake hose maximum length . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0mtr

Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V, 50Hz, 1490W

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46kg

noise level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<87dBA

Specification:

Description:

• Collector Body with Motor • Filter/Collector Bag x 2

• Seal

• Support, Collector x 2

• Base plate

• Screws, Nuts, Washers (1 bag)

• Hose

• Inlet

• Hose Clamp x 2

• Bag Clamp x 2

• Collector

• Inlet Hose (2.5m)

• Support Rod, Filter Bag

• Castors x 4

• Outlet

3. CONTENTS & ASSEMBLY

Note: Numbers in brackets are the item numbers on the parts

diagram and in the parts list.

3.1

Attach the four castors (1) to the underside of the base (3)

using screws (23), washers (16) and nuts (19). support base

(3) on battens, or similar, raising castors clear of floor to give

stability for the following assembly tasks.

3.2

With screws (6) and washers (4) attach motor base (5) to

base (3).

3.3

Attach motor (8) to motor base (5), so that collector body is

positioned as shown in parts diagram, with screws (6) and

washers (4).

3.4

Attach fan housing (38) feet to base plate (3) with screws (6)

and washers (4).

3.5

Install outlet (30) to fan housing (38) using packing (29),

screws (15), washers (16) and nuts (19).

3.6

Attach collector supports (37) to base with screws (12) and

washers (4) and to collector (33) with screws (6) and

washers (4). note that upper bag support (13) is fitted to the

collector (33) with the same screws as the middle support (37).

3.7

fit upper (filter) bag (35) over upper bag flange on collector

(33) and secure by tightening built-in strap. Hook loop on end

of bag (55) over support arm (13). fit second (collector) bag

(36) to lower bag flange on collector.

Note: Bag clamps (34) are provided and may be used for additional

bag security.

3.8

Install hose (32) between outlet (30) and collector (33) and

retain with hose clamps (31).

3.9

Push-fit inlet (24) to inlet cover (25).

unpack the extractor components and check that all are present and

undamaged. In case of shortage or damage please contact the

supplier.

4. OPERATING INSTRUCTIONS

WARNING! before operating the extractor ensure that

you read, understand and apply the safety instructions

in Section 1. 4.1. confirm that supply voltage matches the

voltage shown on the motor data plate and that the motor

switch (9) is ‘off’.

4.2

connect extractor hose (39) to the inlet (24) and attach other

end to extractor point on equipment. If only one extractor

hose is to be used ensure that the unused inlet is closed

with the cap provided.

WARNING! DO NOT operate extractor without the

hose(s) attached.

4.3

Plug into mains supply and press motor switch ‘on’.

4.4

Ensure that the lower bag is emptied of dust and chips on a

regular basis and is not allowed to become full.

Note: fitting a reducer to the extraction hose will reduce the

volume of dust extracted.

WARNING! this unit is not suitable to be used to extract

dust via a piped system.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, suffolk Business Park

,

Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

sM47.V3 Issue: 5 - 05/11/10