4. BATTERY REPLACEMENT

3. OPERATING INSTRUCTIONS

3.1

Hold the tester and make sure that it is at least 20cm away from the object to be tested and

other objects. Then press the

'TEST' button to turn on the tester. '- -' appears on the display

and flashes, then

'mm' appears.

3.2

Press the

'UNIT' button to select the desired unit - 'mm' or 'mil'.

3.3

Place the tester's probe perpendicular to the surface to be tested, the display will show the

coating thickness.

● If the display shows

'- -', it means the tester does not detect any iron, steel or aluminium

substrate.

● If the display shows

'OL', it means that the coating thickness exceeds the tester's

measuring range.

● If the display shows

' - O', it means that the probe has wear or substrate under the coatings

or it may be of a metal other than iron, steel or aluminium.

3.4

When you measure, the reading will remain on the display, move the tester away and press

'TEST' to delete the reading, the display will show '- -'.

3.5

If it does not detect the presence of iron, steel or aluminium in about thirty seconds, it will turn

itself off automatically. To turn the tester off manually, press and hold down the

'TEST' button

for one second.

NOTE: If the temperature changes during measurement turn off the tester and turn it on again and

then make the measurement immediately. This will ensure measurement accuracy.

Different kinds of steel have different magnetic suceptibilities and conductivities, so the

measurement results of coatings on different kinds of steel (substrate) may be different, even

if these coating thicknesses are the same. For coatings on steel, measurement results can

only be used for non-critical reference.

When the low battery indicator appears on the display, the battery must be replaced immediately.

4.1

Make sure the tester has turned off, then rotate the battery cover in the direction indicated by

the arrows on the battery cover.

4.2

Tap the tester on your palm to remove the battery cover and the battery will fall out.

4.3

Install a new cell of the same type (3V button cell, CR2032 or equivalent), make sure the

positive terminal of the button cell will face the battery cover when the cover is installed.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

TA091 Issue No.1 09/09/13

© Jack Sealey Limited

BATTERY DISPOSAL / REPLACEMENT INFORMATION

See Section 4 regarding battery access/ replacement.

Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of

products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance

scheme. Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705

Environmental Protection.

Recycle unwanted materials instead of disposing of them as waste.

All tools, accessories and packaging should be sorted, taken to a recycle

centre and disposed of in a manner which is compatible with the environment.

WEEE Regulations.

Dispose of this product at the end of its working life in compliance with the

EU Directive on Waste Electrical and Electronic Equipment. When the product

is no longer required, it must be disposed of in an environmentally protective

way.

Contact your local solid waste authority for recycling information.