Maintenance, Risk of hand arm vibration injury – Sealey SA623 User Manual
Page 3
![background image](https://www.manualsdir.com/files/846850/content/doc003.png)
p
WarninG! Disconnect screwdriver from air supply before changing accessories, servicing
or performing maintenance. Replace or repair damaged parts. Use genuine parts only.
Non-authorised parts may be dangerous and will invalidate the warranty.
5.1. Lubricate the air screwdriver daily with a few drops of Sealey air tool oil dripped into the air
inlet to prolong its life.
5.2. Clean the screwdriver after use.
5.3. Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or
type of hose connectors. To remedy check the air supply and follow instructions in
chapter 3.
b) Grit or gum deposits in the screwdriver may also reduce performance. If your model has
an air strainer (located in the area of the air inlet), remove the strainer and clean it. Flush
the screwdriver out with gum solvent oil or an equal mixture of SAE No 10 oil and
paraffin. Allow to dry before use.
5.4. For a full service contact your local Sealey service agent.
5.5. When not in use, disconnect from air supply, clean screwdriver and store in a safe, dry,
childproof location.
5. Maintenance
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPortant: No liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
inforMation: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
sole uK Distributor, sealey Group,
Kempson Way, Suffolk Business Park
,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Web
Original Language Version
SA623.V2 Issue: 1 - 17/10/11
risk of Hand arm Vibration injury
Air Pistol Screwdriver, Model No. SA623.V2
, when operated in accordance with these
instructions and tested in accordance with BS EN 28662-1:1993, ISO 8662-1:1988 and
BS EN ISO 28927-2:2009 in the following vibration emission declared in accordance with
BS E
N12096:1996.
Measured vibration emission value: 4.89m/s² uncertainty: 1.96m/s²
These values are suitable for comparison with emission levels of other tools that have been
subject to the same test.
this tool may cause hand-arm vibration syndrome if its use is inadequately managed.
recommended Measures to reduce risk of hand-arm vibration syndrome:
This tool should not be used by an individual regularly for more than 456 m
inutes in any 8 hour
period.
This duration of use should be reduced if the individual is exposed to hand-arm vibration from
other sources.