Maintenance – Sealey GSA722 User Manual
Page 3
WARNING! Disconnect the polisher from air supply before changing accessories, servicing or performing
maintenance. Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be
dangerous and will invalidate the warranty.
5.1. If the air supply system does not include an oiler, lubricate the polisher daily with a few drops of good
grade air tool oil such as Sealey ATO/500S or ATO1000S, dripped into the air inlet before use.
5.2. Clean the polisher after use and change pads when required.
5.3. Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose
connectors. To remedy check the air supply and follow instructions in Section 3.
b) Grit or gum deposits in the polisher may also reduce performance. If your model has an air strainer
(located in the area of the air inlet), remove the strainer and clean it. Flush out the polisher with gum
solvent oil or an equal mixture of SAE No 10 oil and kerosene. Allow to dry before use.
If you continue to experience problems, contact your local Sealey service agent.
5.4. When not in use, disconnect from air supply, clean and store in a safe, dry, childproof location.
5. MAINTENANCE
Original Language Version
© Jack Sealey Limited 2013
GSA722 Issue: 2 (SP) - 19/08/13