Fig.7 fig.8 fig.6 – Sealey SA0615KIT User Manual
Page 6
WARnIng! disconnect the nail/staple gun from the air supply before refilling with nails/staples, servicing or performing any maintenance.
replace or repair damanged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
10.1. If an air system oiler is not available, lubricate the air nail/staple gun daily with a few drops of air tool oil, dripped into the air inlet
before use.
to re-order air tool oil, use sealey part nos. ato500s (500ml) or ato1000s (1 litre).
10.2. clean the nail/staple gun after use.
10.3. loss of power or erratic action may be due to the following:
a) excessive drain on the air line. moisture or restriction in the air pipe. Incorrect size or type of hose connectors. to remedy, check
the air supply and follow the instructions in section 8.
b) Grit or gum deposits in the nail/staple gun may also reduce performance. flush the nail/staple gun out with gum solvent oil or an
equal mixture of sae no 10 oil and kerosene. allow to dry before use. If continuing to experience problems, contact your local
sealey service agent.
10.4. check moving parts alignment, trigger, safety mechanism and spring on a regular basis.
10.5. on a weekly basis, check the security of the hex bolts holding the driver guide plate in place and tighten if necessary (fig.6).
10.6. for a full service, contact your local sealey service agent.
10.7. When not in use, disconnect from air supply, clean nail/staple gun and store in a safe, dry, childproof location.
10. nAIl/stAple gun mAIntenAnce
Original Language Version
sa0615KIt Issue: 2- 20/02/12
fig.7
fig.8
fig.6