beautypg.com

Maintenance – Sealey SA602 User Manual

Page 3

background image

WARNING! Disconnect the wrench from the air supply before changing accessories,

servicing or performing maintenance. Replace or repair damaged parts. Use genuine parts

only. Unauthorised parts may be dangerous and will invalidate the warranty.

5.1 If the air system does not have an oiler, lubricate the air wrench daily with a few drops of

Sealey air tool oil dripped into the air inlet.

5.2 The gearbox can be lubricated by greasing via the nipple on the rear of the wrench head.

5.3 Clean the wrench after use.

5.4 loss of power or erratic action may be due to the following:

5.4.1 Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type

of hose connectors. To remedy, check the air supply and follow the instructions in chapter 3.

5.4.2 Grit or gum deposits in the wrench may also reduce the performance. If your model has an

air strainer located in the area of the air inlet, remove the strainer and clean it. Flush out the

wrench with gum solvent oil, or an equal mixture of SAE No 10 oil and paraffin. Allow to dry

before use.

5.4.3 For a full service contact your local Sealey service agent.

5.4.4 When not in use, disconnect the wrench from the air supply, clean it and store it in a safe,

dry, childproof location.

5. MAINTENANCE

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SA602.V3 Issue: 3 - 14/12/11

Risk of Hand Arm Vibration Injury

1/2” Air Impact Wrench Model: SA602.V3 when operated in accordance with these instructions and tested in

accordance with EN 28662-1: 1994 results in the following vibration emission and vibration declared in

Accordance with BS EN12096: 1996.

Vibration . . . . . . . . .1.2 m/s

²

Uncertainty . . . . . . . 0.48%

These values are suitable for comparison with emission levels of other tools that have been subject to

the same test.

This tool may cause hand-arm vibration syndrome if its use is inadequately managed.

Recommended Measures to reduce risk of hand-arm vibration syndrome:

This item represents a low Hand Arm Vibration risk to users. The calculated minimum usage period exceeds 8

hours. We recommend appropriate safety equipment is utilised and regular breaks for the operator are

employed to reduce any residual risk of fatigue or repetitive strain injury.