Optional fan installation - freestanding, Fan removal - insert, Installation – Enviro Kodiak 1200 Insert User Manual
Page 43
43
The fan kit is pre-installed into the left shroud that comes
with your unit. If a decorative set of shroud plates is
purchased, the fan assembly must be removed from the
shroud to installed the decorative plates (refer to “R
EMOVAL
O
F
T
HE
S
HROUDS
- I
NSERT
”).
1) Disconnect all electrical connections for the fan kit.
2) Remove the four (4) T-20 screws that hold the fan
mounting plate to the shroud. If the fan needs to be
removed from its mounting plate, use a 1⁄4” socket and
wrench to remove the six (6) bolts holding the fan
housing to the plate.
3) Remove the fan control knob and nut from the front of
the shroud and pull the controls out the back.
4) Slide the plug out the front of the shroud.
5) Install the fan kit into the new shroud by following
steps 1 through 4 in reverse order. Refer to F
AN
W
IRING
D
IAGRAM
to ensure the fan is reconnected properly.
F
AN
R
EMOVAL
- I
NSERT
:
Figure 53: Insert Unit with Fan.
Installation
Refer to F
AN
W
IRING
D
IAGRAM
before installing your optional fan
kit.
1. Remove the fan assembly from the box and inspect for any
damage to the assembly. If damage is noticed call your
dealer, distributor or courier company and have components
replaced before installing kit.
2. Remove the knock out at the bottom of the back panel of the
appliance by using a flat head screwdriver as a lever, hook
the tip of the screwdriver under the panel beside the tabs and
push the panel out.
3. Install two (2) T-20 screws into the top two (2) holes. Place
the blower assembly over these two (2) screws.
4. Ensure the temperature sensor will touch the unit when
mounted. If it does not touch, adjust the sensor so it does.
Tighten the two (2) top screws and install the two (2) bottom
screws and tighten.
5. Plug the fan assembly in and check for proper operation.
O
PTIONAL
F
AN
I
NSTALLATION
- F
REESTANDING
:
Figure 52: Back View of Freestanding
Unit with Fan Kit.