beautypg.com

Optional fan installation - freestanding, Fan removal - insert, Installation – Enviro Kodiak 1200 Insert User Manual

Page 43

background image

43

The fan kit is pre-installed into the left shroud that comes

with your unit. If a decorative set of shroud plates is

purchased, the fan assembly must be removed from the

shroud to installed the decorative plates (refer to “R

EMOVAL

O

F

T

HE

S

HROUDS

- I

NSERT

”).

1) Disconnect all electrical connections for the fan kit.
2) Remove the four (4) T-20 screws that hold the fan

mounting plate to the shroud. If the fan needs to be

removed from its mounting plate, use a 1⁄4” socket and

wrench to remove the six (6) bolts holding the fan

housing to the plate.

3) Remove the fan control knob and nut from the front of

the shroud and pull the controls out the back.

4) Slide the plug out the front of the shroud.
5) Install the fan kit into the new shroud by following

steps 1 through 4 in reverse order. Refer to F

AN

W

IRING

D

IAGRAM

to ensure the fan is reconnected properly.

F

AN

R

EMOVAL

- I

NSERT

:

Figure 53: Insert Unit with Fan.

Installation

Refer to F

AN

W

IRING

D

IAGRAM

before installing your optional fan

kit.

1. Remove the fan assembly from the box and inspect for any

damage to the assembly. If damage is noticed call your

dealer, distributor or courier company and have components

replaced before installing kit.

2. Remove the knock out at the bottom of the back panel of the

appliance by using a flat head screwdriver as a lever, hook

the tip of the screwdriver under the panel beside the tabs and

push the panel out.

3. Install two (2) T-20 screws into the top two (2) holes. Place

the blower assembly over these two (2) screws.

4. Ensure the temperature sensor will touch the unit when

mounted. If it does not touch, adjust the sensor so it does.

Tighten the two (2) top screws and install the two (2) bottom

screws and tighten.

5. Plug the fan assembly in and check for proper operation.

O

PTIONAL

F

AN

I

NSTALLATION

- F

REESTANDING

:

Figure 52: Back View of Freestanding

Unit with Fan Kit.