beautypg.com

Installation – Enviro Kodiak 1200 Insert User Manual

Page 29

background image

29

Installation

I

NSTALLATION

OF

A L

ISTED

, F

ACTORY

B

UILT

C

HIMNEY

- F

REESTANDING

:

This is a generic set of instructions; always follow the chimney manufacturer’s instructions

explicitly. Also refer to “R

ECOMMENDED

H

EIGHTS

F

OR

F

LUE

P

IPE

”.

1. Set floor protector and stove in location in accordance with the “C

LEARANCES

T

O

C

OMBUSTIBLES

- 1200

Hearthpad

Floor

Pedestal

Woodstove

Optional

fan

Outside air connection

through wall or floor

Ceiling support

Ceiling

Radiation shield

Insulated chimney

Rain cap/

Spark arrestor cap

Roof flashing

Roof

Attic

radiation shield

Minimum air space in

accordance with

chimney manufacturer.

Chimney

connector

Storm Collar

F

REESTANDING

” or “C

LEARANCES

T

O

C

OMBUSTIBLES

-

1700 F

REESTANDING

”.

2. Mark the position for the ceiling hole by

suspending a plumb bob from the ceiling

over the exact center of your stove flue and

mark a spot on the ceiling to indicate the

center of the chimney.

3. Move this location, if necessary, to avoid

floor joists, ceiling rafters, electrical wiring

and plumbing while still maintaining required

clearances. If floor joists or ceiling rafters

must be cut they must be made structurally

sound again. Install chimney according

to chimney manufacturers instructions. A

chimney connector cannot pass through

an attic or roof space, closet or similar

concealed space, or a floor, ceiling, wall

or partition of combustible construction.

In Canada, if passage through a wall or

partition of combustible construction is

desired, the installation shall conform to

CAN/CSA-B365 Installation Code for Solid-

Fuel Burning Appliances and Equipment and

NFPA 211 Standard for Chimneys, Fireplaces,

Vents, and Solid Fuel-Burning Appliances.

4. Mark the hole for the outside air kit.
5. Move the stove out of the way.
6. Cut a pilot hole in the ceiling.
7. Cut a hole for the ceiling penetration

components and frame in the sides of the

hole in both the ceiling and roof. Check, and

follow chimney manufacturer’s instructions

for all of these steps.

8. Install the support box and chimney through

the roof. Install the slip section for the

chimney connector.

9. Slip the roof flashing over the chimney and

secure to the roof, being careful to keep the

pipe centered in the opening. To meet the

code, the chimney must extend above the

roof penetration at least 3 feet (91.4 cm),

Figure 28: Standard Vertical Installation.

Figure 27: Roof Clearances.