Installation

Hearthpad

Floor

Pedestal

Woodstove

Optional

fan

Outside air connection

through wall or floor

Chimney

connector

Ceiling

Insulated chimney

Roof flashing

Roof

Roof radiation

shield (if required)

Minimum air space

in accordance with

chimney manufacturer.

Wall support

Chase

(optional)

Insulated corner

Minimum

18" (475 mm)

Rain cap/

Spark arrestor cap

Storm Collar

and in any area within 10 feet

(304.8 cm) of the roof ridge,

the chimney must be 2 feet

(60.9 cm) above the ridge.

Refer to Figure 27.

Note: Increasing the chimney

height above the roof may

help your unit to draft better.

This greater draft can decrease

problems such as difficult

start-ups, smoke coming out

when door is open, and dirty

glass. You may initially try

the minimum required height

and if problems do arise, add

additional height later.

10. Slide the roof flashing over

your chimney and seal the

flashing to the roof with a

roofing compound. Secure the

roof flashing to your roof with

nails or screws.

11. Place the storm collar over the

flashing and seal the joints

with silicone caulking.

12. Fasten the rain cap / spark

arrestor cap to the top of your

chimney.

13. Place the stove back into

Figure 29: Standard Horizontal Installation.

position.

14. Install the chimney connector pipe with the lower (crimped) edge of the pipe inside the flue collar.

Any creosote formed will then run back down into the stove. All connections must be tight and

secured with three sheet metal screws equally spaced. Double wall pipe is recommended over single

wall.

15. Also install an outside air flex pipe to the stove.

IMPORTANT: When a metal prefabricated chimney is used, the manufacturer’s installation instructions

must be followed. You must also purchase and install the ceiling support package or wall pass-through

and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc.

Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be

the required height above the roof or other obstructions for safety and proper draft operation.

Note: If you are using a horizontal connector (refer to Figure 29), the chimney connector

should be as high as possible while still maintaining the 18” (475 mm) minimum

distance from the horizontal connector to the ceiling.

30