Specifications

C

LEARANCES

T

O

C

OMBUSTIBLES

- 1700 F

REESTANDING

:

MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*

Table 10: 1700 Freestanding Clearance to Combustibles.

Single Wall Pipe

Double Wall Pipe**

Double Wall Pipe

with Heat Efficiency

Shield 50-1088 (Flat

top model only)

Top vent out back

wall with min. 24”

(610 mm) vertical

rise; double wall

A From side wall

to side of unit

20”

(508 mm)

13”

(330 mm)

13”

(330 mm)

11”

(279 mm)

B From rear wall

to back of unit

12”

(305 mm)

10”

(254 mm)

7”

(178 mm)

13”

(330 mm)

C From adjacent wall

to corner of unit

10”

(254 mm)

81⁄2”

(216 mm)

6”

(152 mm)

D From side wall

to collar

29”

(737 mm)

22”

(559 mm)

22”

(559 mm)

20”

(508 mm)

E From rear wall

to collar

15”

(381 mm)

13”

(330 mm)

10”

(254 mm)

16”

(406 mm)

F

From adjacent wall

to collar

181⁄2”

(470 mm)

17”

(432 mm)

141⁄2”

(368 mm)

G † From door opening

to edge of hearth pad

USA 16” (406 mm)

CND 18” (450 mm)

USA 16” (406 mm)

CND 18” (450 mm)

USA 16” (406 mm)

CND 18” (450 mm)

USA 16” (406 mm)

CND 18” (450 mm)

H † From side/back of unit

to edge of hearth pad

USA 6” (152 mm)

CND 8” (200 mm)

USA 6” (152 mm)

CND 8” (200 mm)

USA 6” (152 mm)

CND 8” (200 mm)

USA 6” (152 mm)

CND 8” (200 mm)

Alcove (48” Deep)

I

Total Width

51” (1295 mm)

J

Total Height

72” (1829 mm)

K Top of stove to ceiling

44” (1118 mm)

L

Side wall to stove

13” (330 mm)

M Side wall to pipe

22” (559 mm)

N Back wall to unit

8” (203 mm)

O Back wall to pipe

11” (279 mm)

CAUTION: An uninsulated smoke pipe must not pass through an attic, roof space, closet or similar concealed

space, or through a floor, ceiling, wall, or partition, or any combustible construction.

FLOOR PROTECTION: If a stove is installed on a combustible floor, it must have a pedestal or leg kit with ash

pan attached and be on a NON-COMBUSTIBLE hearth pad

* ALL CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO THE LOCAL AUTHORITY.

**DOUBLE WALL:

IN CANADA: Any ULC-S629 listed chimney system with the accompanying listed double wall vent connector.

IN U.S.A.: Any UL 103 HT listed chimney system with the accompanying listed double wall vent connector.

�����

�����

������

J

���� ����

��

��

�����

������ ���� ����

��

��

��

��

��

��

�������� ����

��

��

��

I

������

16