beautypg.com

Safety precautions – Enviro Kodiak 1200 Insert User Manual

Page 3

background image

3

Safety Precautions

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD

STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

Please read this entire manual before you install and use your new woodstove. Failure to

follow instructions may result in property damage, bodily injury or even death. Be aware

that local Codes and Regulations may override some items in this manual. Check with your

local inspector.

● If this appliance is not properly installed, operated and maintained, a serious house fire could result.

Do not use any makeshift materials during installation, maintenance, or replacement.

● Never place wood, paper, furniture, drapes or other combustible materials near the stove. Do not let

children or pets touch it when it is hot.

● Operate only with the door and ash pan tightly closed and burn wood directly on the stove hearth. Do

not operate if the door glass is broken or a gasket is missing or damaged. Do not alter the combustion

air control valves. Dangerous overfiring could occur which could ignite creosote in the chimney or

cause a house fire.

● At least 12 square inches (77.4 cm

2

) of fresh outside air should be admitted into the room or directly

to the stove through a 4 inch (10.16 cm) diameter pipe. For the stove to operate combustion-air must

be supplied through either the bottom or the back of the pedestal.

● Do not burn coal or charcoal as there is danger of carbon monoxide being produced. Do not use

chemical fluids to start or re-fresh the fire. Do not burn garbage or flammable fluids such as gasoline,

grease, naphtha or engine oil. Never let the stove become hot enough to get any part red or glowing

red.

● Burning wet, unseasoned wood could cause excessive creosote accumulation in the flue pipe. When

ignited, it could cause a chimney fire that could result in a serious house fire.

● Do not use grates, andirons or any other methods to support or raise the fire up off the hearth of the

appliance.

● This appliance is tested to ULC-S627 Standard for Space Heaters for Use with Solid Fuel, ULC-S628

Standard for Fireplace Inserts, & UL 1482 Standard for Safety for Solid-Fuel Type Room Heaters.

● Both the 1200 & 1700 Fireplace Inserts are approved for installed into a zero-clearance fireplaces in the

U.S. In Canada refer to local building or fire officials for restrictions and installation inspection

● In Canada the existing chimney must be lined to the termination for all masonry installs.

IMPORTANT: The following must be done

to ensure proper operation. Failure to do so

will cause extreme overheating and possible

personal injury or property damage:

• If an outside air supply has not been added to

this appliance, please ensure that the 4” inch

fresh air outlet on the back of the pedestal is

removed.

• Ensure that the ash dump grate and cover

plate are installed over the ash dump hole.