beautypg.com

Maintenance and service, Routine maintenance, Cleaning the glass – Enviro Ascot 50-029 User Manual

Page 7: Cleaning the firebox, Change battery in ignition module

background image

7

Maintenance And Service

R

OUTINE

M

AINTENANCE

:

At least once a year, run through the following procedures to ensure the system is clean and working

properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not

blocked by anything. The pilot flame should be blue with little or no yellow on the tips.
Warning: Clearances must be sufficient to allow access for maintenance and service
Warning: Failure to position the parts in accordance with this manual, or failure to use only parts

specifically approved with this appliance may result in property damage or personal injury.
The venting system must be periodically examined; it is recommended the examination is done by a

qualified agency.

C

LEANING

T

HE

G

LASS

:

When the fireplace has cooled, remove the face of the fireplace along with the glass. See M

AINTENANCE

A

ND

S

ERVICE

- G

LASS

D

OOR

R

EMOVAL

. Check the gasket material on the back of the glass, making sure that it

is attached and intact.
It will be necessary to clean the ceramic glass periodically. During a cold start up, condensation will

sometimes form on the glass. This is a normal condition with all fireplaces. However, this condensation

can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave a slight

film behind the glass, a temporary problem. The glass will need cleaning initially after the first 4 hours

of use and again about two (2) weeks after installation. Use a mild glass cleaner and a soft cloth;

abrasive cleaners will damage the glass and enamal surfaces. Depending on the amount of use,

the glass should require cleaning no more than two or three times a season. Do not clean the glass

when it is hot.

C

LEANING

T

HE

F

IREBOX

:

Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and

place on a paper towel. Vacuum the bottom of the firebox thoroughly. Carefully clean any dust off the

logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or

severe warping. If a problem is suspected, contact the dealer. Check the logs for deterioration or large

amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers

as in the L

OG

S

ET

AND

E

MBER

I

NSTALLATION

section. If new/more embers and rock wool are required, contact

your nearest ENVIRO dealer.

C

HANGE

B

ATTERY

IN

I

GNITION

M

ODULE

:

If the unit does not spark when lighting, the battery in the electronic ignition could need replacing.
The ignition module is located at the far left behind the valve cover (see Figure 6). Remove the battery

cover, located on the left side of the module, and replace the AA battery.
Reinstall the battery cover and check for spark by depressing the pilot knob located on the control

panel.