Initial Installation

E

LECTRICAL

R

EQUIREMENTS

:

The ENVIRO ASCOT will operate without electrical power. This model has a millivolt gas control, which

uses the pilot flame to generate enough electricity to operate the main burners. The appliance when

equipped with an optional blower must be electrically connected and grounded in accordance with local

codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part

1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI

/ NFPA 70 in the U.S.
WARNING: Electrical grounding instructions. This appliance is equipped with a three-prong (grounding)

plug for your protection against shock hazard, and should be plugged directly into a properly grounded

I

NSTALLATION

OF

O

PTIONAL

B

LOWER

:

COOL / HEAT
PROGRAM

DOWN

UP

70 ° F

Blue

Purple

Gas Control

Valve

Thermopile

ON/OFF/Thermostat

Grey

Optional

Thermostat

Pilo

Adjustment

Screw

���

�����

�����

���

�����������

������

�����

�����

���

����������

����� ������

Remove the pre-assembled blower from the

packaging. Inspect the blower for damage. If

damage is noticed call your dealer, distributor

or courier company and have components

replaced.
Place the fan assembly behind the unit and

secure with the two screws provided (as

shown in Figure 31).
Remove the fan controller, mounting box and

install fan controller. Neatly dress the wires

from the fan assembly to the fan controller.
Install the fan temperature sensor with the

two (2) screws provided.
Plug the fan assembly into the wall outlet and

turn the unit on to ensure fan operation.

���� � ���� ��
��� �����������
������

������ ������

��� ����������

��� �����������
������ ������
�������� ���

Figure 31: Optional Fan Kit Installation.

Figure 30. Wiring Diagram For Fan Control.

Figure 29. Wiring Diagram For Gas Valve.

Table 4. Recommended Thermostat Wire Size.

Wire Size

Max. Length

14 gauge

100 ft (30.48 m)

16 gauge

60 ft (18.29 m)

18 gauge

40 ft (12.00 m)

20 gauge

25 ft (7.62 m)

22 gauge

18 ft (5.49 m)

three-prong outlet. DO NOT cut or remove the grounding prong

from this plug.
CAUTION: Label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and dangerous

operation. Verify proper operation after servicing.