Vent restrictor setting, Initial installation – Enviro Ascot 50-029 User Manual

Page 12

background image

12

Initial Installation

V

ENT

R

ESTRICTOR

S

ETTING

:

1

2

3

4

5

1

2

3

4

5

����� ����

���������� �����

����� ������

���������� �����

Refer to Figure 9 to determine were the vent restrictor should be set

for proper operation.
The numbers in the chart represent the actual vent restrictor

settings. Although the numbers do not appear on the unit use this

guide to follow.
Undo the setscrew and adjust the vent restrictor to the correct

setting.
Ensure that the setscrew is retightened and the unit is checked for

proper operation.
Wait for the unit to warm up to operating temperature to ensure a

proper and clean burning unit.
NOTE: The total length of the vent pipes can not exceed 15 feet

(4.6 m). Any combination of rise and run can be used as long as it

lays within the shaded area.

To access restrictor plate, look at

the left hand rear corner of the

unit. There is a small rectangular

hole in the air jacket
Loosen the 1⁄4” hex head bolt and

adjust to the correct setting.
Slide the hex bolt to the next

setting and retighten the bolt to

ensure the plate does not move

Figure 9. Possible Vent Configurations.

Figure 8. Vent Restrictor Settings.