beautypg.com

Trouble shooting – Enviro Ascot 50-029 User Manual

Page 27

background image

27

Trouble Shooting

Problem

Possible Cause

Solution

Spark will not light the

pilot after repeatedly

pressing the spark ignitor

Defective piezo ignitor.

• Check connections to ignitor.

• If ignitor connections are good but no spark, replace

ignitor.

Broken spark electrode.

• Check for broken ceramic insulation, replace

electrode if broken.

Low battery or bad

electronic module.

• Replace the electronic module or replace the battery

in module.

Misaligned spark electrode. • If spark is not arcing from electrode to pilot, loosen

the screws on the pilot base adjust and tighten.

Pilot will not remain lit

Problem with thermocouple

circuit

• Check for proper connection of the thermocouple to

the rear of the valve. If loose, fully tighten lightly.

• Check pilot for full flame impingement around

thermocouple. If flame is too small, check gas

pressure, adjust pilot rate screw, check pilot head for

damage or blockage.

• Check thermocouple voltage at rear of valve. It must

be greater than 7 mV. If low, replace thermocouple.

Air in gas line (pilot dies

while knob is depressed)

• Bleed line.

• Check gas line pressure.

• Contact dealer.

Burners will not remain

lit

Problem with thermopile

circuit

• Check gas line pressure .

• Check for flame impingement on thermopile. If low,

see “Pilot will not remain lit”.

• Check thermopile for minimum of 200mV when

burner is switched on.

• Check wiring to thermostat for breaks.

Flame lifting

Leak in vent pipe

• Check for leaks in vent connections.

Improper vent configuration • Check vent configuration with manual.
Terminal may be

recirculating flue gases

• Check to see if terminal is on correctly.

• May need to install high wind termination cap.

• Contact dealer.

Improperly set vent

restrictor plate.

• See venting section for proper restrictor setting.

Glass fogs up

Normal Condition: after the appliance warms up the glass will clear.

**Due to additives in gas, glass may get hazy during operation** Clean as needed.

Blue Flames

Normal during start up: flames will yellow as the fireplace heats up.

Flames are burning

“dirty” or sooting

Flame impingement

• Check log positioning.

• Check vent restrictor for proper setting.

• See also “Burners will not remain lit.”