Initial Installation

QUALIFIED INSTALLERS ONLY

H

ORIZONTAL

I

NSTALLATION

:

STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are

in the way when the venting system is attached. If this is the case, you may want to adjust the

location of the appliance.

STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the

desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented

towards the wall or floor, as much out of view as possible.

Place a bead of Mil-Pac on the

outer edge of the inner exhaust

pipe (non-flared end). Place a bead

of high temperature silicone on the

male edge of the outer pipe. Push the

pipe sections completely together,

then twist-lock one section clockwise

approximately 1⁄4 turn, until the two

sections are fully locked. The female

locking lugs will not be visible from

the outside, on black pipe. They may

be located by examining the inside of

the female ends as shown in Figure

12.

Notes:
(1) Twist-lock procedure: four (4) indentations, located on the female end of the pipes and fittings, are

designed to slide straight onto the male ends of adjacent pipes and fittings, by orienting the four pipe

indentations so they match and slide into the four entry slots on the male end.
(2) Horizontal runs of vent pipe must be supported every three feet. Wall straps are available for this

purpose, also when running horizontal pipe minimum clearances to combustibles must be maintained; 2

inches (5.1 cm) at top, 11⁄2 inches (3.8 cm) at sides, 11⁄2 inches (3.8 cm) at bottom.

Sealant

Female

Locking

Lugs

Male

Locking

Lugs

Figure 12: Twist-Lock Connection

Woodscrews

Wall Thimble

Strap

Sheet metal

screws

Fold strap

here

1

1

/

4

"

(3.2cm)

Figure 14: Installing Decorative Wall Thimble.

10"

(254mm)

10"

(254mm)

Figure 13: Wall Framing Hole for

Horizontal Installation.

14