cap assembly. It is important that the vent pipe

extend into the vent cap a sufficient distance

with a minimum of 11⁄4” (3.2 cm) overlap.

Secure the connection between the vent cap

pipe and the vent cap by attaching the two

sheet metal straps extending from the vent

cap assembly into the outer wall of the vent

pipe. Use the two sheet metal screws provided

to connect the straps to the vent pipe. Bend

any remaining portion of the sheet metal straps

back towards the vent cap, so the decorative

wall thimble will conceal it (see left image in

Figure 14).

STEP 7. Slide the decorative wall thimble up to the wall

surface and attach with the screws provided.

Apply decorative brass or chrome trim if desired

(see right image in Figure 14).

NOTES:
(1)
The four wood screws provided should be replaced

with the appropriate fasteners for stucco, brick,

concrete, or other types of siding.

(2) For buildings with vinyl siding, a vinyl siding

standoff, should be installed between the vent cap

and the exterior wall (see Figure 15). Attach the

vinyl siding standoff to the horizontal termination.

The vinyl siding standoff prevents excessive heat

from possibly melting the vinyl siding material. Note

that the horizontal vent termination bolts onto the

flat portion of the vinyl siding standoff (shaded area

in Figure 15), so that an air space will exist between

the wall and the vent termination.

Initial Installation

QUALIFIED INSTALLERS ONLY

Figure 15: Installing Vent Cap with Vinyl Siding

Stand-Off.

Figure 16: Installing Horizontal Vent Termination.

STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x

10” (25.4 cm) square hole (refer to Figure 13). The center of the square hole should match the

center line of the horizontal pipe. Cut and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the

exterior wall where the vent will be terminated. Refer to Figure 8. If the wall being penetrated

is constructed of non-combustible material i.e. masonry or concrete, a 7 inches (17.8 cm) hole

is acceptable.

STEP 4. Position the horizontal vent termination in the center of the 10” (25.4 cm) x 10” (25.4 cm)

hole, and attach to the exterior wall with the four screws provided. Before attaching the vent

termination to the exterior wall, run a bead of non-hardening mastic around the edges, so as to

make a seal between the termination and the wall. The arrow on the vent termination should be

pointing up, insure that the proper clearances to combustible materials are maintained.

STEP 5. Before connecting the horizontal run of the vent pipe to the vent termination, slide the black

decorative wall thimble cover over the vent pipe.

STEP 6. Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the