Hearth mount installation, Initial installation – Enviro Ascot 50-029 User Manual

Page 22

background image

Initial Installation

H

EARTH

M

OUNT

I

NSTALLATION

:

This unit may be installed as a hearth mounted unit.
Install two 3’ inch pipes up the chimney to a seal plate and cap assembly, one exhaust pipe, and one air

intake pipe
Using venting manufactures coaxial to co-linear adapters at the unit and at the chimney termination.
Maximum vertical chimney height 15 feet (4.57 m)

15 feet (4.57m)

Maximum

Vertical Venting

If installed

on a carpeted

surfacea hearth

is required

2"-3" (51mm-76mm)

Collinear Pipes

Existing Masonry

Chimney

Lock Damper in

the Open Position

Seal Plate &

Cap Assembly

Coaxial to

Collinear

Adapter

Figure 28: Hearth Mount Installation.

22