68

Model IFT9701 Transmitter Instruction Manual

IFT9701 Specifications

continued

A.3.3

Humidity limits

5 to 95% non-condensing

A.3.4

Vibration limits

Meets IEC 68.2.6, 2 g, endurance sweep, 10 to 2000 Hz, 50 sweep cycles

A.4

Density limits

0.2 to 2.0 g/cc (200 to 2000 kg/m

3

) for volume flow

0.0 to 2.0 g/cc (0 to 2000 kg/m

3

) for mass flow

150

100

130

80

110

140

90

120

70

158 167 176 185 194 203 212 221 230 239 248 257 266

Maximum, with no

external heat source

Process fluid temperature, °F

Expe

cted

maximum

a

m

bien

t temperature

, °F

Maximum, when mounted

in direct sunlight

30

70

75

80

85

90

95

100 105 110 115 120 125 130

35

40

45

50

55

60

Process fluid temperature, °C

Expected m

a

xim

u

m

a

m

bien

t temperature

, °C

Maximum, with no

external heat source

Maximum, when mounted